To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

PI Interfaces

Showing 253

Uni-Int to write to scan-class health tags on startup

We've noticed this particularly with the RDBMS-PI interface when configured for failover: Health tags that are only written to when the interface becomes primary or has completed its first scan (eg Point Count, Scan Class I/O Rate etc.) say 'Intf ...
Guest over 3 years ago in PI Interfaces / General 0 No status

Separate commonly used PI Interfaces that do not have a successor into read-only and write-only versions

Currently, it is recommended to use the read-only version of a PI Interface if only reading is required, and to have separate read and write instances of the read-write version of a PI Interface if writing is required. (Reference: https://docs.osi...
Kenneth Barber over 3 years ago in PI Interfaces / General 1 No status

OPC AE: add history recovery feature

There is a stronger market demand to have more alarm data in PI so that the alarms can be analysed together with the process data. Existing (as of Oct 2019) PI OPC AE Interface does not support history recovery. Without the history recovery featur...
AM(CSL) over 3 years ago in PI Interfaces / Other Interfaces 0 No status

EMDVB - Add Option to End Procedure EF with batchview.endtime equivalent instead of when it's unloaded from the BOI

Currently the EMDVB interface will not end the parent Procedure level event frame until the batch has been unloaded from the Delta Batch Operator Interface. It is very common for users to leave batches loaded for quite a while which causes batches...
Bill Sublette 12 months ago in PI Interfaces / Batch Interfaces 0 No status

Batch interfaces keeping merged child operation EventFrames open until the parent Operation EventFrame has been closed.

Currently for batch interfaces using the /MUP parameter, child operation event frames might be reopened and closed multiple times until the last operation event frame closes and the child event frame is closed for good. For example with UnitProced...
Guest almost 2 years ago in PI Interfaces / Batch Interfaces 0 No status

EMDVB Data Type Enhancement

Please include option in the DeltaV EMDVB interface that can handle the timestamp format used with .evt files. Currently, if in the interface a trigger is used with a property, the timestamp format in the .evt file is retained, which cannot be sto...
Gary Moore about 1 year ago in PI Interfaces / Batch Interfaces 0 No status

Enhance pitopi.ini sections to include point source to make them unique

The pitopi.ini file is used by the pitopi interface for collecting data from multiple sources and to save other miscellaneous settings such as 'histonly' flags. The configuration ini file uses sections to separate settings between instances with a...
Guest over 3 years ago in PI Interfaces / PI to PI Interface 2 No status

PItoPI should give indication when it is stuck querying a corrupt source archive

Currently, PItoPI interface can get "stuck" if it is querying a source data archive that is corrupt with no indication that this is what's happening.  It appears to be sending data to the destination server, but no data is received.  It ...
Guest over 3 years ago in PI Interfaces / PI to PI Interface 1 No status

Support Analysis Backfill of Source Tag

Many of our source tags sending data to a central Data Archive are populated with data from analyses on the source AF Server. This creates two problems when we perform a backfill that recalculates data over a specified timespan for the source tag:...
Guest over 3 years ago in PI Interfaces / PI to PI Interface 0 No status

PI EFGen 4.1+ has limited recovery capabilities

Up to PI EFGen 4.0, we were able to backfill OOO Event Frames by simply inputting the start and end time of the corresponding period. Since 4.1, this must be done in a per-event basis, since larger time ranges are modified so that RST matches the ...