To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 600

PI Connector for IEC 60870-5-104 bi-directional between SCADA and PI

RWE Power AG “But one really important feature we need, is the ability to write back from PI into the SCADA system Until now, we couldn’t find anything about this (important) functionality. So our question is if we can use this connector bi-dire...
Guest over 3 years ago in PI Connectors / General 4 Declined

Option to remove/edit template prefix

Allow for connectors to create templates without the fixed prefix. E.g. The option to name an AF template "templatename" and not "UFL.templatename"
Guest over 3 years ago in PI Connectors / General 0 No status

PI Connector for Apache Kafka / Confluent

Dear Connector Experts, for our Enterprise data integration project we have the need to use Apache Kafka / Confluent as the "data highway". This requires to send data to PI DA/AF from Kafka and also to read from PI DA/AF back into Kafka. I know ...
Gerrit Stapper over 3 years ago in PI Connectors / New PI Connector Request 3 Declined

OPC UA Connector Trend Advise Option

OPC UA Connector Trend Advise Option, such as in the UniInt interfaces
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 5 No status

Have option to enable exception on Connectors.

There are use cases where data is sent over networks with latency (satellite link, for example) so being able to filter out noise at the connector is important.  This is also important when a connector sends data to a local PI Server in the f...
Brent Bregenzer over 3 years ago in PI Connectors / General 5 No status

Enable Relay/DCM to allow control over the data streams and destination PI Systems

Currently the Relay will send all data streams to all routed destination. This does not allow customers to have control over what data streams go to a specific destination. The only workaround is to have independent Connector/Relay pairs with spec...
Nico Cha over 3 years ago in PI Connectors / General 1 No status

PI Connector for ICCP

Implementation a connector that supports the ICCP TASE 2 protocol
marcogiunti over 3 years ago in PI Connectors / New PI Connector Request 2 Declined

Enable Table-Valued Functions to use parameters more than once

Currently Table-Valued Functions only support the use of a parameter once. For example, once the parameter has been used in another table Valued function like: ... crossapply Master.Element.GetSummary <...> (e.ID, @StartTime, @EndTime) I am ...
Frederik Reinhard 9 months ago in AVEVA™ PI System Access (PSA) / PI SQL Client 0 No status

Add DATEADD and DATEDIFF functions to PI SQL Commander

When any time related functions need to be performed against timestamp columns in PI SQL Commander, one needs to utilize a significant amount of conversions to make this work. For example, if one needs to round timestamps to the nearest minute or ...
Guest over 3 years ago in AVEVA™ PI System Access (PSA) / PI OLEDB Enterprise 0 Declined

PI SQL Client to make use of the RecordedValue method and Retrieval Modes for the GetValue transposed function

When making use of the GetValue transposed function when creating a new Template specific Data Model, we can see that under the hood it makes us of the AF SDK call AFData.InterpolatedValue method to capture the data at a specified timestamp provid...
Guest over 3 years ago in AVEVA™ PI System Access (PSA) / PI SQL Client 1 No status