Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

AVEVA™ PI Server

Be able to resize the sections of the Functions pane in PI System Explorer

The upper edge of the blue part of the Functions pane should be resizable. If this edge is moved upwards, the entire function description can be viewed without having to scroll. If this edge is moved downwards, more functions in the list can be vi...
Kenneth Barber about 4 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Button to Move Variable to Top of Analysis

It would be nice to have a button in PI System Explorer that would move a variable to the top of the analysis, in addition to the buttons that can move a variable up and down.
Jaedyn Larson about 4 years ago in AVEVA™ PI Server / Analytics & Calculations 1 Declined

XOR operator for expression analyses

AF (and PE) expressions currently have AND and OR operators. These work either logically or (if both operands are integer) in a bitwise fashion. There should also be an XOR operator that works the same way, to avoid the messy construct (A AND NOT ...
tinklerj about 4 years ago in AVEVA™ PI Server / Analytics & Calculations 1 No status

Allow analyses to trigger after MaxTime has passed

Trigger analyses "On Any" but also allow for a MaxTime and trigger after MaxTime has passed. Helpful to keep the timestamp current.
Guest about 4 years ago in AVEVA™ PI Server / Analytics & Calculations 0 Declined

Analysis Preview Results - Automatically scroll to result row

After generating "Preview Results" (from right mouse click on analysis name on PSE Analysis Templates tab) it would be nice if the upper results table would auto scroll to the related time value when using the trend cursor to click on the results ...
Guest about 4 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Safeguard against multiple analyses writing to the same PI Point

Safeguard against multiple analyses writing to the same PI Point. Currently it is possible to configure more than one analysis to write to the same PI point. This is a problem since it often goes undetected until someone looks at the data and sees...
Guest about 4 years ago in AVEVA™ PI Server / Analytics & Calculations 2 No status

Allow Calculation Wait Time to be set at the analysis rather than server level

The CalculationWaitTimeInSeconds applies to the entire server but different calculations will have differing requirements of promptness and accuracy (and accuracy can be mitigated with the Recalculation option)
Guest about 4 years ago in AVEVA™ PI Server / Analytics & Calculations 2 No status

New AF analyses should be automatically backfilled a set time interval upon creation.

There should be an option in PSE to automatically backfill all AF Analyses a set time interval upon creation that can be set once. This would prevent a user from having to manually backfill analyses individually or in a group from the Management p...
Guest about 4 years ago in AVEVA™ PI Server / Analytics & Calculations 2 No status

Provide a mechanism to export Analyses and Notifications Management searches.

We create the same Analyses and Notifications on multiple servers. This is easy to do using the database export mechanism. But that export does not include Analyses & Notifications Management searches. So, then, it is necessary to recreate the...
kliffhopson about 4 years ago in AVEVA™ PI Server / Analytics & Calculations 2 No status

Allow BadVal to handle 'No Data' when querying before input tag creation

It is currently not possible to use BadVal and if-then-else logic to handle the 'No Data' system digital state which is returned by a formula data reference or analysis data reference attribute when one of the input tags for the calculation was cr...
Guest about 4 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status