To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 3304

Check history of data discovery in the OPC UA Connector for a data source

Need the option to check historical data discovery dates and times from an OPC UA Connector's data source. There is a Last Discovery performed in the DATA SOURCE TOOLS, however, we should be able to see all of the "Last Discovery" of the data source.
Adam Paranick 3 months ago in PI Connectors / PI Connector for OPC UA 0 No status

Allow user-configured custom names for sites on the Customer Portal

I would like to be able to nickname my organization's sites on the Customer Portal so that they can be easily identified by users who create cases or download products. The names given to the sites are not always clear to the users and are sometim...
Guest over 2 years ago in Customer Portal & PI Square / Customer Portal Overall 2 No status

Correct existing values

Our customers are often asking for a way to manually correct the existing data. They expect to have a table view of all archived values with timestamps during a certain period of time with capability to change the value and enter a comment.
Guest over 2 years ago in AVEVA™ PI Vision™ / Manual Data Entry 1 No status

Add Kerberos Authentication for PI Asset Analytics

Currently, PI Asset Analytics utilizes NTLM authentication. My customer's MSFT Windows Ops team does not recommend using NTLM and by default have this deactivated. Request is to add support for Kerberos authentication for PI Asset Analytics as ...
Guest over 2 years ago in AVEVA™ PI Server / Security 0 No status

PI Connector for Wonderware Historian should be configurable to use 'FULL' mode query

The connectors should have a standard behavior. We believe the Wonderware connector should be collecting data in the same way as the Cygnet connector by getting all the data stored in the source historian irrespective of the value change. Currentl...
Guest over 2 years ago in PI Connectors / PI Connector for Wonderware Historian 0 No status

Enable setting tag attributes in MQTT Connector

The MQTT Connector should have ways to set tag attributes. There should be way to set the default compression and exception settings and also other tag attributes like point and data security.
Guest over 2 years ago in PI Connectors / Other specific PI Connector 1 No status

OPC UA 2.x - Health information and connector statistics

In the PI Connector for OPC UA 1.3.x, some very useful statistics are available - Events in DA queue, Data rate, Variables Numbe - but 2.0.x these items are not available anymore. Those items should be available for data selection to be monitored ...
Gabriel Verreault over 2 years ago in PI Connectors / PI Connector for OPC UA 0 No status

Allow the AF root element name to be configurable

The root element in AF is determined by the Connector code.  Allow the name of the root element to be specified by the user.
Clint Ramsey over 2 years ago in PI Connectors / General 4 No status

Put a REST endpoint on all connectors

It would be very useful to see the data flowing through a connector at the edge, or even the data buffered in a connector. Every connector could have a rest endpoint with the same methods as PI Web API. Possible uses: -Diagnose connection/configu...
Guest over 2 years ago in PI Connectors / General 1 No status

PI Archive ability to recover from drive disconnect

With everyone having virtual servers these days the host VM and SAN storage are on separate devices. When the storage device is unavailable or disconnected even briefly, the PI Archive process errors and gets DISABLED and can ONLY be restarted by ...
Guest over 2 years ago in AVEVA™ PI Server / Data Archive 1 No status