Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 135

Backfill/republish data from select streams used in the PI to ADH transfer

I would like the ability to resync data between my PI Data Archive and AVEVA Data Hub for select streams to easily recover any discrepancies.
Guest almost 2 years ago in PI to CONNECT / General 0 No status

Provide additional features to support debugging

When first setting up the agent, there can be scenarios where there a number of errors to work through - for example tag not found. Summarization of errors and an alternative to event viewer would aid debugging.
Guest almost 2 years ago in PI to CONNECT / General 0 No status

Improve the message for performing on demand History Recovery on datacollectionmode: "CurrentWithBackfill" and "CurrentOnly"

Running edgecmd to perform HR on demand on the datasource: datacollectionmode of Non HistoryOnly. will return the following error: Operation Failed: NotFound (404)Unexpected error: Unexpected character encountered while parsing value: 0. path '", ...
Ee Sheing Lee over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Visibility into Stale Data

Ability to see how stale data is. Do I expect to see data but it hasn't been updated in a long while?
Guest over 3 years ago in PI to CONNECT 2 No status

Support Custom Prefix on PI to CONNECT Streams

I am bringing some of my customers' PI Data into CONNECT. I would like to be able to add a prefix to the data within a particular transfer, because it is very possible my customers could have PI tags with the same name, and even PI Servers that ar...
Guest over 3 years ago in PI to CONNECT 2 No status

Include information from Json body in the stream name created by the MQTT Adapter

As a system admin I would like to send mqtt messages from multiple devices to a single topic on an mqtt broker. Each message would contain data for the device along with a field to say which device the data has come from. Then I would like to use ...
Guest over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

Adapters using Text parser be able to dynamically generate the stream name or ID based on fields of the text parsed

This could be a good feature for any adapters that uses the text parser. MQTT, SDF, Azure Event Hubs. When using JsonPath or Xpath to parse a file or payload the stream name and stream id have to be hardcoded their value cannot be based on a the v...
Randy Giguere about 2 years ago in AVEVA™ Adapters / General 0 No status

BACnet Trend Log Object Collection.

BACnet TrendLog is an object that a controller may implement. Once configured, it’ll keep in memory a certain number of records for one particular point. It functions as a buffer in BACnet controllers to hold historical data in the event of discon...
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for BACnet 0 No status

PI Agent backfill historical value changes

If PI to CONNECT agent goes down, when it comes back online it should be able to capture any changes made in the data history (beyond just backfilling the data between the time it went down and when it came back online).
Max McKay over 1 year ago in PI to CONNECT / General 0 No status

scaling/scale data selection(s)

Simplify data management, setting scale at source
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status