Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

AVEVA™ PI Server

Showing 1291

Allow output expressions when using implicit Event Frame generation modes

In AF/Analytics 2018, implicit modes of Event Frame generation were introduced (Pulse, Step, and Step Continuous), but they do not allow for an output expression like the explicit trigger. Adding this functionality would allow for EF attribute val...
Guest over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 2 No status

Allow different naming for Parent and Child Event Frames

Allow a different naming pattern for the child event frames. End result would have the long, uniquely named EFs in the Parent EF as usual, but the Child EFs could have a simplified name, like the level of an alarm that is pulled from an attribute ...
Guest over 2 years ago in AVEVA™ PI Server / Event Frames (EF) 7 No status

Support for localized element and attribute names

As an user, I want to be able to have a localized element and attribute name in addition to the base language, so that my users do not have to learn a different language.
Guest over 2 years ago in AVEVA™ PI Server / Asset Framework (AF) 2 Declined

OIDC authentication with federated accounts (through CONNECT) requires too many steps

Currently, it is a 5-step process to get authenticated. After the first authentication, it is only a 3-step process, but still clunky.
Laurie Dieffenbach 24 days ago in AVEVA™ PI Server / Security 0 No status

Support UOMs across AF databases within an organization

UOM conversions done on one AF Instance cannot be referenced by another AF Instance, even for the base/built-in UOMs. A customer uses an AF pattern where they have a golden (reference) AF structure that is referenced by other AF structures to help...
Laurie Dieffenbach 24 days ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

Allow changes to pitimeout table (tuning parameters) to be audited

I can be helpful when tracking down issues or troubleshooting past events what the values of tuning parameters were at a given time. Adding the ability to Audit this table would allow retrospective insight into tuning parameter configurations. A ...
Guest over 2 years ago in AVEVA™ PI Server / System Management 0 No status

PI SMT's Current Values plug-in should have an option to not display comma separators for large numbers.

PI System Management Tools currently displays comma separators for large numbers. For example: 1,000,000. As a PI admin/user, it would be beneficial if there was an option to remove these commas.
Bethany Jewett 2 months ago in AVEVA™ PI Server / Data Archive 0 No status

PI Analysis Service should pick up change in Cache Refresh Interval of AF Tables

It would be nice if the PI Analysis Service could pick up a change in the Cache Refresh Interval of any AF Table being referenced by input attributes with a table lookup data reference. Currently, a service restart is required.
Guest over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 5 No status

Attachment in a Notifications from a file path

As an AF administrator, I  would like to send in an attachment of a Notification files that are specified by file path in AF attributes. I currently do this by specifying the value at start time of an AF attribute that contains the changing f...
Guest over 2 years ago in AVEVA™ PI Server / Notifications 0 No status

Enable headers for SOAP Web Service Notifications

The feature added in 2017 R2 was for authentication of the SOAP payload, not for managing headers within the payload.  PI remains unusable as a secure source of data for Maximo without it because you can't configure a MAXAUTH header. There's...
Guest over 2 years ago in AVEVA™ PI Server / Notifications 4 No status