To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Search results: PI Interface for OPC DA

Showing 24 of 3181

Allow automatic interface restart based on Device Status

In some cases, such as when using a tunneller, the PI interface for OPC DA requires a restart to resume collecting data. A feature that allows an automatic restart of the service based on the value of the Device status Health tag would avoid human...
Alberto Tedesco over 2 years ago in PI Interfaces / PI Interface for OPC DA 1 No status

Convert incoming string data to float and provide division all in the same tag instead of a PE

OPC server is outputting data with the currency data type (VT_CY) and it needs to be stored in the float type.  As per the OPCtoCSV document, the OPCtoCSV tool/OPC interface invokes VariantChangeType in order to convert this currency value to...
jagdish.konathala over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Monitor data throughput for PI OPC DA interface

Just knowing if the interface service is running is not enough. Knowledge of data throughput, events/sec, of PI OPC DA interface is needed to know if the OPC DA server is up and running and there are no connection issues.
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 Completed

Add a configuration option to the OPC DA Interface so that the user can adjust the maximum advise tag exception delay for Event/Trigger tags

This affect to delay in Event\Trigger points. KCS: Delay in Event Points. When using Event Points, we purposefully do have a delay (if excMax is > 2 s then 2 s else 0.9*excMax) for advise tags (Trigger Point) before they're sent to the PI Serv...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Add a configuration option to UniInt so that the user can adjust the minimum wait time for checking for new events from the Update Manager

This affects the delay in Event\Trigger tags. KCS: Delay in Event Points. The largest and most variable delay seems to come from the time the event is written to the PI Server and the time the interface (UniInt) picks, which is between 0ms-1,000m...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Any Patches/Updates needed to be ready for Microsoft's DCOM hardening in 2023?

By March 2023 Microsoft will enforce a patch that upgrades DCOM security. Some applications that use DCOM (such as the PI OPC interface) will require some updates to continue to work. Are there any updates that I need to apply on any of the PI com...
James_Podobea about 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

PI interface for OPC DAの配列型タグ対応

PI interface for OPC DAを配列タグ対応にしてほしい。東芝製DCSのデジタルデータの場合、状態を配列型で存在している(例:種別「PB8」、ITEM「LS1」の場合8ビット。種別「PB4」、ITEM「SS1」の場合4ビット)。この値を取得する際、1ビットずつ取得した後にAF演算で1つの値に計算している。対象全タグに対してこの処理を行うことは大変なので、interfaceのところで一度に全ビット取得し、1つの値として取り扱いたい。
kurokuro about 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

PI Interface for OPC DA and VT_ARRAY|VT_BSTR datatype

PI Interface for OPC DA has a plugin called "Time Array" to manage numerical arrays but string arrays are not supported. It would be a good improvement to develop this feature for string arrays.
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Modifying the functionality of Trend Advise feature for PI OPC interface

As a PI OPC Interface user I would like to get step-like trends whenever that the Trend Advise parameter is enabled (even with having large exception and compression deviations that filter some of the events) so that I don't need to enable the ste...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

debug an arbitrary number of tags belonging to a PI OPC interface instance

It is currently possible to debug one tag, or all tags. Logging timestamp and data for all tags is expensive and make logs harder to read, so one one would like to select an arbitrary number of tags.
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 Declined