To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Search results: AVEVA™ PI Server

Showing 122 of 258

Allow Analysis timestamp override feature to output milliseconds

When using an analysis variable as the output timestamp, it appears that the actual output timestamp is floored to the nearest second, shaving off any millisecond count. This is not a huge priority on our end, but I wanted to ask in case it was a ...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Eliminate the 2-cell-wide blank border around PI Builder data

When I import data using PI Builder, I usually want to filter the data and create calculated columns, but these prove to be more painful than necessary. If I put filters on the columns containing PI Builder data and then click on the filter dropd...
Kenneth Barber over 3 years ago in AVEVA™ PI Server / PI Builder 6 No status

Minimize the recalculation of volatile cells

Currently, PI Builder data is imported row by row. Each imported row causes all volatile cells in all open workbooks and any cells downstream of them in the dependency tree to recalculate. PI Builder will not import a new row until this calculatio...
Kenneth Barber over 3 years ago in AVEVA™ PI Server / PI Builder 1 Declined

Create event frames with minimum, maximum, and standard deviation attributes

If a user has PI points that are calculated with average, maximum, and standard deviation time range method, it would be great if those points can be referenced as attributes in an event frame template. Right now the time context needed to calcula...
Guest over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 2 Completed

Refrain from creating PI Points when AF Analytics is doing an expensive calcultion

If it can be known that the Analytics service is busy with an expensive calculation, the Data Archive should pause on creating PI Points, as this is also an expensive operation and may interfere with the calculation completion.
Laurie Dieffenbach about 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Add a performance counter which can measure if Event frame reconciliation is performed correctly

Currently we only can tell an event frame reconciliation is performed by the green check after auto calculation, and it is not very easy to monitor. Since event frame usually use for alarms to operators. Accuracy is very important. We try to avoid...
Guest about 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Make a point class similar to "base", but without zero, span, or typical value

Most of the time, zero, span, and typical value are unused, cause confusion, and/or lead to easy but costly mistakes. Typical value is probably the most useless PI Point attribute. It doesn't affect the PI system. It is just there for the user's ...
Kenneth Barber over 3 years ago in AVEVA™ PI Server / Data Archive 0 Declined

Option to turn off interpolation for a PI Point

Currently, PI will always interpolate to determine a value for a PI Point between archived events. The Step attribute determines the interpolation method. "On" means "step interpolation" and "off" means "linear interpolation". This works well for ...
Kenneth Barber over 3 years ago in AVEVA™ PI Server / Data Archive 3 Declined

Add security concept for Analytics Expressions at the analysis level

As an organization I want to keep confidential calculations secured even inside the same organization. Currently we can control Analytics  r/w access on the Database level. Often this is not enough granularity and the organization will want t...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 Declined

New analysis service installation not forcing the current one to stop

Customer would like to have the following possibility: During the installation of a new Analyses service kit pointing to a PI AF server where an analysis service is already configured, he would like to prevent the current PI analyses service from...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 Declined