Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Search results

Showing 19 of 161

After manually updating data, the next scheduled publish should ensure it does not publish duplicates

As a PI Integrator user, if I use the manual "Update Data" option to correct a time period that includes data that will be published on the next scheduled publication run I do not want this next scheduled run to publish duplicate rows. For example...
Guest over 3 years ago in PI Integrators / AVEVA™ PI Integrator for Business Analytics 0 No status

Add a configuration option to the OPC DA Interface so that the user can adjust the maximum advise tag exception delay for Event/Trigger tags

This affect to delay in Event\Trigger points. KCS: Delay in Event Points. When using Event Points, we purposefully do have a delay (if excMax is > 2 s then 2 s else 0.9*excMax) for advise tags (Trigger Point) before they're sent to the PI Serv...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Retire 32-bit versions of PI Interfaces that have a 64-bit version

These days, 32-bit operating systems are used for 1 of 2 reasons: Somebody accidentally installed the 32-bit version instead of the 64-bit version, which is a mistake that OSIsoft has no obligation to accommodate. The computer is very old, in whic...
Kenneth Barber over 3 years ago in PI Interfaces / General 1 No status

Send Notification When Publish Job Complete

Not sure this would help with continuous jobs, but for large jobs that are scheduled to run one time (for example: publish last 2 years of history) it would be nice to be able to have PI Integrator send off a notification when the job is complete....
Guest over 3 years ago in PI Integrators / AVEVA™ PI Integrator for Business Analytics 0 Declined

BUG: GE HABConnect with BitContainers

I have a case that was closed in 2017, where someone provided a workaround executable for the Interface that fixed the issue. I am assuming they were able to detect a bit container field if the MASK was set for the pitag, but unsure. However after...
Guest almost 3 years ago in PI Interfaces / General 0 No status

PI Interface for GE HABConnect support of SCTIME request

Currently, the PI Interface for GE HABConnect supports FLDTIME requests, which provides the timestamp of the field device.  In the absence of this, the default is the timestamp of the Sampler when HAB API makes an unsolicited update to the in...
Guest over 3 years ago in PI Interfaces / Other Interfaces 0 No status

PI Interface for CA ISO ADS - Allow retrieval of individual items under the Instruction Details xml field

PI Interface for CA ISO ADS can extract data from XML fields. Under the Instruction Detail field, there are multiple MW, serviceType, and segNo fields. Presently, retrieving those values in a PI tag (for example, instrument tag "MW,ResID") returns...
Guest over 3 years ago in PI Interfaces / Other Interfaces 0 No status

Improve writer performance to Amazon Redshift for views with multiple shape matches

Currently, PI Integrator for Business Analytics takes much longer time to write to the Amazon Redshift target for views with multiple matches. For below example, View 1: 1 shape match with 300 rows of data View 2: 300 shape matches with 1 row of d...
Ting-Ying Chung almost 3 years ago in PI Integrators / AVEVA™ PI Integrator for Business Analytics 0 No status

DNP3 Interface specify Class for scans

Create some way to configure PI Points belonging to a DNP3 interface instance such that the interface only requests data for a single class (Class 1/Class 2/Class 3) and not all three? Essentially, an event scan that will request one specified Cla...
Guest over 3 years ago in PI Interfaces / PI Interface for DNP3 0 Declined