To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Search results: AVEVA™ PI Server

Showing 210 of 781

Use %Duration% with Formula Data Reference as Best Practice for EF Duration Attribute (AF 2017 R2+)

This is a followup to discussions with Roger Palmen and Rick Davin about their excellent writeups on the topic of EF Duration attributes; see Event Frame duration - easy way in AF2.6 or higher & Duration attribute on an Event Frame - Part 1 , ...
Brent Bregenzer over 3 years ago in AVEVA™ PI Server / Asset Framework (AF) 1 Declined

Add relevant windows service dependency via installer.

Following KB01345 & 000036461 we have to manually add dependency where applicable. Please consider adding similar service dependency than we have via PI ICU for new interface (depend on pibufss): - AFService depend on relevant MSSQL$ service ...
Guest over 3 years ago in AVEVA™ PI Server / Installation 1 No status

As an administrator, I would like to be able to backfill data that crosses over a versioning event

Use case: 1. An element has an attribute that looks up information on equipment configuration (ex: a pump rate) 2.  Due to an equipment change, the lookup table and the element were increased in version 3. A backfill needed to be performed o...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 1 No status

Use dynamic endpoints to subscribe AF Groups to Notification Rules.

We have several sites, and a corresponding AF Group with personnel local to each site. We would like to configure the AF Element Template for sites to send a daily notification to the corresponding group for each site. This can only be done by add...
Gregory Malek about 1 year ago in AVEVA™ PI Server / Notifications 0 No status

Export Analysis Search

In the management tab of PSE, allow the option to export the defined analysis searches. When a user receives a new computer, all of the defined searches have to be recreated.When this spans development, quality assurance and production environment...
Tim Carmichael over 2 years ago in AVEVA™ PI Server / Asset Framework (AF) 1 No status

High availability options with Big-IP F5 for Notifications and Analytics instead of only Windows Clustering?

We have redundant servers for AF components (Notifications & Analytics). In a virtual environment, our IT doesn't support Windows Clustering due to the way storage is implemented enterprise wide. What does it take to support F5? Our IT engin...
jagdish.konathala over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 2 Declined

Override output timestamp when the output is also input for the analysis

If the output of your analysis is also used as an input for the analysis, the option offset the output timestamp relative to the trigger time is grayed out and you see the message "Cannot override output time stamp if any output is used as an inpu...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 2 Tell us more

Trigger notification email when event frame has been acknowledged

I would like to configure notifications such that an email is sent when the event frame has been acknowledged.
Guest over 3 years ago in AVEVA™ PI Server / Asset Framework (AF) 1 No status

Properly handle Event Frame edits on Event Frames that are generated by the PI Analysis Service

Users manipulate open event frames that are generated by the PI Analysis Service. The manipulation can be: 1) Write to an attribute on the EF 2) Write an annotation 3) Acknolwedge the EF When these manipulations are being performed the Event Fra...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 5 Declined

PI EFGen interface : allow configuration of events without OS-admin rights

PI EFgen interface is built in such a way that it is not possible to configure events without Windows-Admin rights on the machine hosting the interface. This is not relevant in term of security and we would like to let key-users configure events w...
Guest over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 2 No status