Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Search results: AVEVA™ Adapters

Showing 10 of 10

OPC UA Adapter: support Namespace index change after OPC UA Server restart

AVEVA adapter for OPC UA should support changes in the Namespace index that can happen after an OPC UA Server service restart. Currently, if the Namespace index of the source signals change, the adapter stops receiving data for every point in that...
Alvaro Bilbao about 1 month ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Sampling/Publishing Interval parameters to be part of Data Selection description

When configuring the AVEVA Adapters in general, we would find more convenient to be able to define the ‘Sampling Interval’ and 'Publishing Interval' parameters inside the ‘Data Selection’ configuration per each data stream. For instance, when desc...
Christian Leroux over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

PI Adapter for OPC UA should preiodically retry to subscribe to each node for which subscription failed at startup

Currently the PI Adapter for OPC UA tries to subscribe to all the OPC UA nodes configured in the Data Selection configuration at startup. However, when as issue occurs during the subscription to an OPC UA node, that node will not be included in da...
Bernard Lafrance over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Enable subscribe using wildcard for AVEVA Adapter for MQTT

It would be handy to have the PI Adapter for MQTT to be able to subscribe to a broker by using wildcards only. Right now, we need to specify each individual topics on the data selection rule, and this eventually comes as individual subscription as...
Tombayu Hidayat 8 months ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

Enable Auto Discovery for PI Adapter for MQTT SparkplugB to always listen for Birth and Death messages

When utilizing the SparkplugB protocol for MQTT, it would be beneficial for the adapter to be always listening for birth and death messages from specific Edge of Network nodes. This way, the device can send a birth message to have itself added t...
Guest about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 1 Tell us more

Adapters using Text parser be able to dynamically generate the stream name or ID based on fields of the text parsed

This could be a good feature for any adapters that uses the text parser. MQTT, SDF, Azure Event Hubs. When using JsonPath or Xpath to parse a file or payload the stream name and stream id have to be hardcoded their value cannot be based on a the v...
Randy Giguere over 1 year ago in AVEVA™ Adapters / General 0 No status

Allow PI Adapter for MQTT to log the raw json payload received from the broker

For troubleshooting, it can be very helpful to see the raw json payload that the adapter has received from the broker, rather than just the error response from the attempted parsing. It can be difficult to know why a parsing attempt has failed wit...
Guest about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 2 Future consideration

PI Adapter for (generic) MQTT to enable auto-discovery of key value pairs using wildcards

When reading from a generic MQTT broker, we currently need to specify explicitly each key value pairs we want to collect inside the data selection json configuration file. This prevents us from really being agile at the time of the initial setup a...
Guest about 3 years ago in AVEVA™ Adapters / General 0 Completed

Provide additional time formatting options for RDBMS Queries

Background: Today we are collecting data from our AspenTech IP21 Server thorugh the PI Adapter for OPC UA and the related AspenTech OPC UA Server. This works perfectly fine for analogue data but not for data which is providing us equipment status ...
Hans-Otto Weinhold almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for RDBMS 1 Tell us more

Better support of IP21 OPC UA Server with PI Adapter for OPC UA

We have been using the PI Adapter for OPC UA in its current version to collect data from IP21 OPC UA Server during a lighthouse project. However, the configuration was a bit cumbersome since the OPC UA Server of AspenTech uses an opaque mechanism ...
Hans-Otto Weinhold about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status