Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 20 of 5194

Modify the Modbus Interface to accept 32-bit Unsigned Ints from the PLC

provide a data type to accept a 4 byte unsigned integer from the PLC.  At this point, it would be stored in a 64-bit float in PI DA.
Clint Ramsey over 3 years ago in PI Interfaces / PI Interfaces for Modbus 3 Declined

RDBMS Interface version that support the failovertime > 20s (UFO_Interval)

If you have a query that lasts longer than 40s and a phase2 failover configuration is used. The interfaces switch constantly from primary to secondary and viceversa. With the parameter "UFO interval" you can control this behavior. However, this pa...
MiguelPalomo over 3 years ago in PI Interfaces / PI Interface for RDBMS 1 Declined

Log bad timestamps for the PI RDBMS Interface

When the PI RDBMS Interface gets a bad timestamp from the source RDB that it cannot coerce into a PI Timestamp, the actual bad timestamp received from the RDB should be logged as part of the error message. This would coincide with the following e...
Guest over 3 years ago in PI Interfaces / PI Interface for RDBMS 0 Future consideration

Support multiple Modbus devices on the same machine

Add support for multiple Modbus devices (using the same IP address but different port numbers) on the same machine. For example, the interface could allow the user to configure something like this: /dn= xxx.xx.xxx.xx:43120,/cn=1,/polldelay=0,/to...
Guest over 3 years ago in PI Interfaces / PI Interfaces for Modbus 3 Declined

Add Mod10 to Custom Data Type Manipulator for Modbus Interface

Please add support for SquareD Mod10 custom datatype to the Modbus Interface. Schneider Electric uses a custom datatype that uses four 16 bit registers. Each register represents an integer. Each integer is then multiplied by a factor and all resu...
Guest over 3 years ago in PI Interfaces / PI Interfaces for Modbus 0 No status

Alert user when the interface discards values

Example:  When using a distribution tag, the number of tags returned and number of values sent to PI can be mismatched, due to missing aliases or data that does not need to be collected. It would be helpful to identify what values are droppe...
Guest over 3 years ago in PI Interfaces / PI Interface for RDBMS 0 No status

Test Modbus Serial interface with newer Operating Systems

Currently the Modbus Serial interface supports Windows 7 as the latest possible operating system. Please test the Modbus Serial interface version 4.0.7.61 with operating systems such as Windows 10 or 11. Or release a new Modbus Serial interface th...
Rachel Morgenroth about 3 years ago in PI Interfaces / PI Interfaces for Modbus 0 No status

Provide support for Modbus function code 20

Provide support for Modbus function code 20
Guest over 3 years ago in PI Interfaces / PI Interfaces for Modbus 0 No status

RDBMS time stamp precision

Currently the ODBC connection is configured with a SQL date time parameter when retrieving the TS parameter (snapshot time stamp). Due to the fact lots of sources system having more precision in their time stamps, it makes it hard to compair sourc...
meierke1 over 3 years ago in PI Interfaces / PI Interface for RDBMS 0 No status

RDBMS - Failover delay for specific situation when the interface encounters a ODBC failure/disconnect

RDBMS - Failover delay for specific situation when the interface encounters a ODBC failure/disconnect
AlexMeade almost 3 years ago in PI Interfaces / PI Interface for RDBMS 0 No status