To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 77 of 5194

Support move/rename of Attributes specified by path in Asset-based Calculation expressions

Currently, if an element or attribute is moved or renamed, any Asset-based Calculations in PI Vision with an expression that uses an AF path containing that element or attribute will return "No Data" as it is no longer be able to find that attribu...
Jason Lu about 2 months ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

ICU startup on high latency networks

On high latency networks, it can take ICU many minutes to start because every interface on the PI Data Archive is checked. Minimize startup time by caching a node's registered interfaces.
Guest over 3 years ago in PI Interfaces / PI Interface Configuration Utility (PI ICU) 11 Future consideration

Allow bar graphs in trends

Add bar graphs as an option for trends
kimmyberly26 over 3 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 2 No status

Remote PI ICU

Regardless of where interface info are stored (PI Module DB or AF), it would be useful to have a remote client tool allowing administrator users to configure interfaces  like they do with tags and AF objects. Today when you have to change con...
MAl over 3 years ago in PI Interfaces / PI Interface Configuration Utility (PI ICU) 2 No status

Migrate the PI ICU settings away from the PI Module Database

PI ICU settings are currently the main reason why the PI Module Database continues to live on even the most up-to-date PI systems. Please consider migrating the PI ICU settings from the PI Module Database to the PI Asset Framework or a separate fi...
Kenneth Barber over 3 years ago in PI Interfaces / PI Interface Configuration Utility (PI ICU) 5 No status

Use calculation as tags

It would be nice to be able to propagate calculations within PI by calling for other calculated variables within a new calculation. For example, where X, Y, and Z are PI Tags, I have a calculation A = X+Y. I would like to add a new calculation B...
Guest over 3 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 1 No status

Display's Start/End Time in Vision Calculation

be able to have a Vision calc utilize the current start and end time of the display
Matt Voll over 3 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 1 No status

Multistate does not recognize value in calculation (Text)

Allow multistate to recognize text
Guest 4 months ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

Use a calculation in another calculation

Currently, you cannot use a calculated variable in another calculation on PI Vision. This complicates calculations because all operations must be done under one calculation.
Navern Moodley over 1 year ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

Calculated tags present value error

For calculated tags when being trended for more than ~12 hours time frame, the trend works fine except for the live present value, the calculation can be completely off. See attached screenshot for an example, where several tags are checked whethe...