To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 15 of 5194

Properly link comments, verifications and approvals to batches

When Unit Procedure level criteria are used to link a report template to batches, it is possible to select any Unit Procedure, Operation, Phase or step to generate the report. Whatever the selected Unit Procedure, Operation, Phase or step, the ge...
cmartineau almost 3 years ago in AVEVA™ RtReports / Generator 0 No status

RDBMS Interface version that support the failovertime > 20s (UFO_Interval)

If you have a query that lasts longer than 40s and a phase2 failover configuration is used. The interfaces switch constantly from primary to secondary and viceversa. With the parameter "UFO interval" you can control this behavior. However, this pa...
MiguelPalomo over 3 years ago in PI Interfaces / PI Interface for RDBMS 1 Declined

Log bad timestamps for the PI RDBMS Interface

When the PI RDBMS Interface gets a bad timestamp from the source RDB that it cannot coerce into a PI Timestamp, the actual bad timestamp received from the RDB should be logged as part of the error message. This would coincide with the following e...
Guest over 3 years ago in PI Interfaces / PI Interface for RDBMS 0 Future consideration

Prevent an user from approving more than once

When a report has multiple approval cycles with the same group (or with different groups that have some people in common), it would be useful to have the option of preventing the same user from completing all approval cycles, so that they must be ...
Guest about 3 years ago in AVEVA™ RtReports / Generator 0 No status

pop-up to confirm the end of Approval cycle

It woul be useful to have a pop-up confirming that the approval cycle is properly completed.
Monica Rattaggi GSK almost 2 years ago in AVEVA™ RtReports / Generator 0 No status

Alert user when the interface discards values

Example:  When using a distribution tag, the number of tags returned and number of values sent to PI can be mismatched, due to missing aliases or data that does not need to be collected. It would be helpful to identify what values are droppe...
Guest over 3 years ago in PI Interfaces / PI Interface for RDBMS 0 No status

RDBMS time stamp precision

Currently the ODBC connection is configured with a SQL date time parameter when retrieving the TS parameter (snapshot time stamp). Due to the fact lots of sources system having more precision in their time stamps, it makes it hard to compair sourc...
meierke1 over 3 years ago in PI Interfaces / PI Interface for RDBMS 0 No status

RDBMS - Failover delay for specific situation when the interface encounters a ODBC failure/disconnect

RDBMS - Failover delay for specific situation when the interface encounters a ODBC failure/disconnect
AlexMeade almost 3 years ago in PI Interfaces / PI Interface for RDBMS 0 No status

Add option to select interface behavior for bad timestamps (PI RDBMS)

When the PI RDBMS Interface gets a bad timestamp from the source RDB that it cannot coerce into a PI Timestamp, the interface attempts to use the current timestamp instead and logs the following error: "pitm_settime() error - 15002. Using current...
Guest over 3 years ago in PI Interfaces / PI Interface for RDBMS 0 No status

Accept weeks and years in the relative time syntax for history recovery start and end times

For whatever reason, times such as *-1w or *-1y are not accepted, but times such as *-1mo and *-1d are OK. Please make the PI Interface for RDBMS accept the same relative times that other PI programs accept.