To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 16 of 5217

remote ingress to EDS

Enable remote access to EDS OMF endpoint to support deployments where Adapter/OMF application is installed on different host/network to EDS because architecture must fit in with tiered networks for critical asset security. For example remote sites...
Guest over 3 years ago in Edge Data Store / Ingress 3 Future consideration

RDBMS Interface version that support the failovertime > 20s (UFO_Interval)

If you have a query that lasts longer than 40s and a phase2 failover configuration is used. The interfaces switch constantly from primary to secondary and viceversa. With the parameter "UFO interval" you can control this behavior. However, this pa...
MiguelPalomo over 3 years ago in PI Interfaces / PI Interface for RDBMS 1 Declined

Log bad timestamps for the PI RDBMS Interface

When the PI RDBMS Interface gets a bad timestamp from the source RDB that it cannot coerce into a PI Timestamp, the actual bad timestamp received from the RDB should be logged as part of the error message. This would coincide with the following e...
Guest over 3 years ago in PI Interfaces / PI Interface for RDBMS 0 Future consideration

EDS: OPC DA Connector

Ability for OPC DA connector to write data to Edge Data Store.
Guest over 3 years ago in Edge Data Store / Ingress 1 Declined

Alert user when the interface discards values

Example:  When using a distribution tag, the number of tags returned and number of values sent to PI can be mismatched, due to missing aliases or data that does not need to be collected. It would be helpful to identify what values are droppe...
Guest over 3 years ago in PI Interfaces / PI Interface for RDBMS 0 No status

EDS: Modbus Serial Connector

Ability for Modbus Serial connector to write data to Edge Data Store.
Guest over 3 years ago in Edge Data Store / Ingress 1 Declined

RDBMS time stamp precision

Currently the ODBC connection is configured with a SQL date time parameter when retrieving the TS parameter (snapshot time stamp). Due to the fact lots of sources system having more precision in their time stamps, it makes it hard to compair sourc...
meierke1 over 3 years ago in PI Interfaces / PI Interface for RDBMS 0 No status

Documentation of EDS Modbus TCP Adapter needs to be updated on removed 32-bit register support for Modbus TCP Adapter

Challenge: The current version of PI Adapter for Modbus TCP does not any longer support 32-bit Holding/Input registers as this is outside of the Modbus specifications. However, in some cases, 32-bit register values have to be read from 16-bit regi...
Hans-Otto Weinhold over 2 years ago in Edge Data Store / Ingress 0 Planned

RDBMS - Failover delay for specific situation when the interface encounters a ODBC failure/disconnect

RDBMS - Failover delay for specific situation when the interface encounters a ODBC failure/disconnect
AlexMeade almost 3 years ago in PI Interfaces / PI Interface for RDBMS 0 No status

Add option to select interface behavior for bad timestamps (PI RDBMS)

When the PI RDBMS Interface gets a bad timestamp from the source RDB that it cannot coerce into a PI Timestamp, the interface attempts to use the current timestamp instead and logs the following error: "pitm_settime() error - 15002. Using current...