To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 15 of 5194

Allow AVEVA Adapter for Modbus TCP to collect data on INT64 and UINT64 registers

Certain equipment is providing energy data under INT64 or UNIT64 register types. However, the Adapter currently only supports FLOAT64, which is not compatible. We want to be able to configure the Adapter for Modbus TCP to collect data on INT64 and...
Alexa Derago 3 months ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 Future consideration

Synchronize behavior between PI Connector for Cygnet and Cygnet enumeration value representation

The values stored in the “Table Entry” column in Cygnet TRS should match the “State” column in the PI Server Digital states table. This way end users are not confused why the trends in PI do not match the trends in Cygnet.
Guest over 3 years ago in PI Connectors / PI Connector for CygNet 0 No status

Support VHS point History recovery for PI Connector for Cygnet

VHS points in Cygnet contain historical data. On startup, disconnection and at will, the connector should should attempt to recover history.
Guest over 3 years ago in PI Connectors / PI Connector for CygNet 0 No status

Enhance the PI Connector for Cygnet Back Fill Utility to use select PI Points

Currently the back filling utility for the PI Connector for Cygent only permits back filling an entire data source. Sometimes it is desirable to back fill certain points, or a subset of a data source, that has missing data or gaps that need to be ...
Guest over 3 years ago in PI Connectors / PI Connector for CygNet 0 No status

Cygnet - Check for prerequisites during the installation process instead of in the logs on startup

Currently, if some Cygnet prerequisites are missing, the following error is logged: Although the errors are clear, this verification step should also occur during the initial installation process. Please review the "Installation requirements for...
Gabriel Verreault over 3 years ago in PI Connectors / PI Connector for CygNet 0 No status

Cygnet connector should not update old archives unless being backfilled

No description provided
Guest over 3 years ago in PI Connectors / PI Connector for CygNet 0 No status

Capability to disable a data source within connector configuration

No description provided
Guest over 3 years ago in PI Connectors / PI Connector for CygNet 0 No status

Allow PI Connector for Cygnet to support a mix of VHS and CVS when Automatic UDC Recognition is enabled

With Automatic UDC recognition enabled, PI Connector for Cygnet defaults to placing all UDC's in the CVS column by default, or in the VHS column if "Prefer VHS for Automatic UDC recognition" is checked. This behavior should be a preference, not a...
Guest over 3 years ago in PI Connectors / PI Connector for CygNet 0 No status

Expand Healthpoint (Device Status) Information of the PI Adapter for Modbus TCP from Component to "Device" Level

When configuring PI Modbus TCP adapter you first define a component level and under this type you define your different devices/machines/sensors. In case of a broken connection to one of the devices the healthpoints currently only deliver the stat...
Mario Amrhein about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Support for "RTU over TCP" for Modbus Adapter using MBAP header

Challenge: Today, the PI Adapter for Modbus TCP does not natively support " RTU over TCP". It does support Modbus TCP, so as long as the "bridge" properly converts Modbus RTU to Modbus TCP (including the MBAP header), it should work fine. If the b...
Hans-Otto Weinhold about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status