To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 16 of 5199

RDBMS Interface version that support the failovertime > 20s (UFO_Interval)

If you have a query that lasts longer than 40s and a phase2 failover configuration is used. The interfaces switch constantly from primary to secondary and viceversa. With the parameter "UFO interval" you can control this behavior. However, this pa...
MiguelPalomo over 3 years ago in PI Interfaces / PI Interface for RDBMS 1 Declined

Log bad timestamps for the PI RDBMS Interface

When the PI RDBMS Interface gets a bad timestamp from the source RDB that it cannot coerce into a PI Timestamp, the actual bad timestamp received from the RDB should be logged as part of the error message. This would coincide with the following e...
Guest over 3 years ago in PI Interfaces / PI Interface for RDBMS 0 Future consideration

Alert user when the interface discards values

Example:  When using a distribution tag, the number of tags returned and number of values sent to PI can be mismatched, due to missing aliases or data that does not need to be collected. It would be helpful to identify what values are droppe...
Guest over 3 years ago in PI Interfaces / PI Interface for RDBMS 0 No status

Provide OSIsoft partners access to all software licenses for evaluation; think MSDN, VMware, Rockwell Toolkit, etc.

Please make it easier for OSIsoft partners to access the software and solutions that we’re expected build expertise and offerings around. It feels far more difficult than it should for us to have connectors, interfaces, integrators, etc. added to ...
Guest over 3 years ago in Customer Portal & PI Square / Partner Portal Overall 0 No status

Add support for TLS 1.3

Please add support for TLS 1.3 to partners.osisoft.com so that it loads more quickly and more securely.
Kenneth Barber over 3 years ago in Customer Portal & PI Square / Partner Portal Overall 0 No status

Enable OCSP stapling on partners.osisoft.com

OCSP stapling means the web server sending the certificate revocation status with the certificate to the users' browsers, which avoids the need for the browsers to contact the certificate authority to get this information. OCSP stapling will make ...
Kenneth Barber over 3 years ago in Customer Portal & PI Square / Partner Portal Overall 0 No status

RDBMS time stamp precision

Currently the ODBC connection is configured with a SQL date time parameter when retrieving the TS parameter (snapshot time stamp). Due to the fact lots of sources system having more precision in their time stamps, it makes it hard to compair sourc...
meierke1 over 3 years ago in PI Interfaces / PI Interface for RDBMS 0 No status

RDBMS - Failover delay for specific situation when the interface encounters a ODBC failure/disconnect

RDBMS - Failover delay for specific situation when the interface encounters a ODBC failure/disconnect
AlexMeade almost 3 years ago in PI Interfaces / PI Interface for RDBMS 0 No status

Add option to select interface behavior for bad timestamps (PI RDBMS)

When the PI RDBMS Interface gets a bad timestamp from the source RDB that it cannot coerce into a PI Timestamp, the interface attempts to use the current timestamp instead and logs the following error: "pitm_settime() error - 15002. Using current...
Guest over 3 years ago in PI Interfaces / PI Interface for RDBMS 0 No status

Accept weeks and years in the relative time syntax for history recovery start and end times

For whatever reason, times such as *-1w or *-1y are not accepted, but times such as *-1mo and *-1d are OK. Please make the PI Interface for RDBMS accept the same relative times that other PI programs accept.