To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

AVEVA™ Adapters

Showing 117

Error handling for OPC UA Server nodes with "Null" data type

Using a combination of Honeywell Experion OPC UA and the Aveva OPC UA Adapter, we have observed that when an instrument physically fails in the field or goes offline / stops sending communication to the Experion server, it may appear in the Honeyw...
ChrisMcKee 2 days ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Pi adapter OPCua able to rename pi-tags

As per title
Rob Chew 28 days ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 2 Tell us more

The DNP3 Adapter should support group 40

The interface supports this group. The Adapter does not (see https://docs.aveva.com/bundle/adapter-for-dnp3/page/1231146.html). It is essential that the Adapter have this identical feature as the interface, to allow it to read the same data and be...
Daniel Lopez about 1 month ago in AVEVA™ Adapters / AVEVA Adapter for DNP3 0 No status

Adapter should have the ability to read from a TCP Socket

In a lighthouse project we needed to read from a TCP Socket. Ideally the Adapter for Structured Data files would be able to read from a socket and process its data.
Fabio Dani about 1 month ago in AVEVA™ Adapters / AVEVA Adapter for Structured Data Files 1 No status

Support for the Galileosky Protocol

Need an option for direct integration of Galileosky GPS tracking devices with the AVEVA PI System without third-party middleware. The devices primarily use the proprietary Galileosky binary protocol (TCP-based, port 20332 by default) for real-time...
Mohammed Qasim Asghar about 2 months ago in AVEVA™ Adapters / New Connectivity 0 No status

Start/stop components to be retained on restart

Currently it is possible to stop a component for a running adapter. However, if the adapter is restarted the component will automatically start up. It would allow for extra control during commissioning, downtime, incidents, etc. to be able to disa...
Mike Horrocks about 2 months ago in AVEVA™ Adapters / General 0 No status

Include the "Include variables having historical data only" flag for the OPC UA Adapter

The OPC UA Connector has a feature that should also be included with the AVEVA Adapter for OPC UA : UserAccessLevel=HistoryRead - No real time data to subscribe for and only has historical data stored Please add this feature to the adapter.
Joshua Weishaar 2 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Tell us more

Allow AVEVA Adapter for Modbus TCP to collect data on INT64 and UINT64 registers

Certain equipment is providing energy data under INT64 or UNIT64 register types. However, the Adapter currently only supports FLOAT64, which is not compatible. We want to be able to configure the Adapter for Modbus TCP to collect data on INT64 and...
Alexa Derago 4 months ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 Future consideration

Egress via AF SDK

Please add AF SDK Egress as an additional optional egress component. This would be very helpful for customers who are using the adapters, but keeping the PI Server on-premise. The adapters are relatively light-weight services; however, the “cost” ...
sahilp 5 months ago in AVEVA™ Adapters / General 0 No status

OPC UA Adapter Create Tag on Discovery

For the OPC UA Adapter, we are noticing that a tag won't be created until a data point comes in after the tag is added to the data filter. That causes issues for slow updating tags. For instance an open/shut valve that is rarely operated. We have ...
Damon Vinciguerra 5 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Future consideration