Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Batch Interfaces

Showing 24

Have the FTB Interface support multiple stop events for Unit Procedures

There are instances where a batch must be manipulated creating two Unit Released events in the event file. The desired behavior for the PI FactoryTalk Batch Interface would be for the second end time to overwrite the first end time when data is be...
Guest 16 days ago in PI Interfaces / Batch Interfaces 0 No status

Have the FTB interface not truncate the trailing "-#" index (e.g. UnitProcedureName-1) at the end of a Unit Procedure

Some FactoryTalk batch processes have overlapping Unit Procedures with trailing indexes. Because the trailing index is truncated it results in overlapping Unit Procedures with the same name which are then merged. The desired behavior would be for ...
Guest 16 days ago in PI Interfaces / Batch Interfaces 0 No status

Have the FTB interface capture "Active Step Change Commencing" events as event frames

Some FactoryTalk batch processes require "Active Step Change Commencing" event to be part of the batch hierarchy however the PI Interface for Factory Talk Batch starts event frames only on [EVENT] = "System Message" or "State Change".
Guest 16 days ago in PI Interfaces / Batch Interfaces 0 No status

Update EFGen Interface Health Tags To Allow For Better Status Monitoring

The current EFGen interface "Status" health tag displays a value of "Good" if it is connected to the data source but does not factor in if it is writing Event Frame data to PI. There is not currently a straightforward way to drive a PI Notificatio...
Guest over 2 years ago in PI Interfaces / Batch Interfaces 2 No status

EFGEN - Allow Zeroth State strings to be used with Digital-type Active Points

When my EFGen Active Point tags have a type of digital, the interface should allow certain digital states to be designated as a Zeroth State.
Guest over 2 years ago in PI Interfaces / Batch Interfaces 1 No status

Link Referenced Elements from Unitprocedure to Procedure Event

When Eventframe Batches are created by a Batch Interface, the used Unit in the plant is created as Element in AF and linked to the Unitprocedure EventFrame. Unfortunately it is not linked to the parent Procedure Event, leaving the "referenced Elem...
juergen.b.schmidt over 2 years ago in PI Interfaces / Batch Interfaces 0 No status

Support Werum PAS|X 3.2 and PAS|X Data Access (PDA)

Werum has recently released the next version of their PAS|X Database, and it bolsters a new method of Data Access. OSIsoft will need to release an re-tooled version of their PI Interface for Werum PAS|X to support this latest Werum version and the...
Ellery Murdock over 2 years ago in PI Interfaces / Batch Interfaces 1 No status

Batch interfaces keeping merged child operation EventFrames open until the parent Operation EventFrame has been closed.

Currently for batch interfaces using the /MUP parameter, child operation event frames might be reopened and closed multiple times until the last operation event frame closes and the child event frame is closed for good. For example with UnitProced...
Guest 9 months ago in PI Interfaces / Batch Interfaces 0 No status

efgen

Allow EFGen to use a Mix of PITAG + Text for the Creation of event frame names . Concatenate a Text + PITAG for example
valeman over 2 years ago in PI Interfaces / Batch Interfaces 4 No status

Allow diagnostic tags per failover node for batch interfaces

Batch interfaces should allow for diagnostic tags per failover node, just like UniInt based interfaces. Currently, there is no differentiation between the diagnostic tags for the primary failover node versus the backup failover node. The Location3...
Guest over 2 years ago in PI Interfaces / Batch Interfaces 0 No status