Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 88 of 5194
344 VOTE

Connector-level Failover - OPC UA 2.x

Support connector-level failover in PI Connector for OPC UA 2.x (relay-enabled version). Similar to UniInt failover (interfaces), failover should be data source specific and always favor the data source in the better state.
Gabriel Verreault over 3 years ago in PI Connectors / PI Connector for OPC UA 35 Declined
118 VOTE

PI OPC UA Connector Array support

Add reading capability for OPC UA Arrays. Currently items with “ValueRank“ = 1 are ignored.
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 11 No status

Retrieve data even it's not changed on OPC server

Currently Connector configured to rertieve event on change and not based on a scan class like interfaces.The Connector suscribes to the changes, and when a change comes in to the server, the data will be sent to PI connector. We need option to ret...
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 13 Declined

OPC UA server failover based on watchdog tag

Gen2 PI Connector for OPC UA support OPC UA server level failover. How the Connector determine when to failover to the other OPC UA server: As per 6.6.2.4.2 ServiceLevel , this is used by the client to determine whether to connect/disconnect fro...
Ee Sheing Lee about 1 month ago in PI Connectors / PI Connector for OPC UA 1 No status

Do not synchronize description from OPC UA server into PI Tag

There are situations when customer prefers to use “description” in PI Tag attribute that is independent from item “description” provided by OPC UA Server.   Currently, during each synchronization, the OPC UA Connector synchronizes descri...
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 10 In development

ICU startup on high latency networks

On high latency networks, it can take ICU many minutes to start because every interface on the PI Data Archive is checked. Minimize startup time by caching a node's registered interfaces.
Guest over 3 years ago in PI Interfaces / PI Interface Configuration Utility (PI ICU) 11 Future consideration

OPC UA: allow historical data access

allow historical data access with custom time ranges, like OPC HDA
Clint Ramsey over 3 years ago in PI Connectors / PI Connector for OPC UA 11 Declined

Remote PI ICU

Regardless of where interface info are stored (PI Module DB or AF), it would be useful to have a remote client tool allowing administrator users to configure interfaces  like they do with tags and AF objects. Today when you have to change con...
MAl over 3 years ago in PI Interfaces / PI Interface Configuration Utility (PI ICU) 2 No status

Get data by polling

Support acquiring data by polling the OPC UA server rather than subscription.
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 4 Declined

Migrate the PI ICU settings away from the PI Module Database

PI ICU settings are currently the main reason why the PI Module Database continues to live on even the most up-to-date PI systems. Please consider migrating the PI ICU settings from the PI Module Database to the PI Asset Framework or a separate fi...
Kenneth Barber over 3 years ago in PI Interfaces / PI Interface Configuration Utility (PI ICU) 5 No status