To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

AVEVA Adapter for OPC UA

Showing 20

Please add a feature for the OPC UA adapter to enable the adapter to only store values with a good status or rather filtering out bad values

When receiving bad values from the OPC UA Server to the adapter there is no option to filter out bad values. So these values get stored in the Data Archive and are causing problems with analyses (e.g. expression or Event Frame generation). At the ...
Timur Eroglu about 2 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No Status

PI Adapter for OPC UA should preiodically retry to subscribe to each node for which subscription failed at startup

Currently the PI Adapter for OPC UA tries to subscribe to all the OPC UA nodes configured in the Data Selection configuration at startup. However, when as issue occurs during the subscription to an OPC UA node, that node will not be included in da...
Bernard Lafrance about 2 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No Status

Add the option "Ignore Bad_WaitingForInitialData Status"

In the connectors there was the option "Ignore Bad_WaitingForInitialData Status", as described here. For gen 1 there was a need to edit the config files directly, and in gen 2 the option was integrated into the UI. Instead for the adapter I recent...
sahilp 6 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No Status

When using debug mode level tracing in opc ua, can we get a dump of the client settings and data source settings in the log file that are being used so we know the context of that session?

it will tell us exactly the full context the adapter is operating in when it starts up and connects to the data source.
Clint Ramsey 9 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No Status

Ua Server force failover / improve failover logic

Let me preface this by saying that I know it is a workaround for a non-compliance with the OPC UA specifications. The point is that the situation described below is unfortunately all too common and the workaround is needed. It often happens that t...
sahilp 9 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No Status

Better support of IP21 OPC UA Server with PI Adapter for OPC UA

We have been using the PI Adapter for OPC UA in its current version to collect data from IP21 OPC UA Server during a lighthouse project. However, the configuration was a bit cumbersome since the OPC UA Server of AspenTech uses an opaque mechanism ...
Hans-Otto Weinhold 9 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No Status

Prevent PI Adapter for OPC UA from modifying/override stream overrides and metadata upon restart

Problem: I have configured PI Adapter for OPC UA to collect data from an OPC UA Server. Since UoMs are not assigned properly, I created stream overrides in AVEVA Data Hub to assign the proper UoM to the particular stream. I also associated stream ...
Hans-Otto Weinhold 9 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No Status

PI Adapter for OPC UA should send the previous value when it has been with the same value for a long time

"This enhancement request proposes a solution to address the issue of data interpolation between two values far apart in time in adapter data collection. The suggestion is to include the value right before the new data point, ensuring the fidelity...
Fabio Dani 10 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No Status

GUI Front End for UA Adapter

The OPC UA Adapter is a replacement for the OPC UA Connector and should thus provide similar functionality by providing a GUI.
Jonathan Brutt 11 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 3 Future Consideration

Sampling/Publishing Interval parameters to be part of Data Selection description

When configuring the AVEVA Adapters in general, we would find more convenient to be able to define the ‘Sampling Interval’ and 'Publishing Interval' parameters inside the ‘Data Selection’ configuration per each data stream. For instance, when desc...
Christian Leroux 12 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No Status