Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 10

Fully support local viewing and storage of health and diagnostics streams and assets in EDS

Currently, the health and diagnostics streams for EDS are only viewable at the configured health endpoint such as CDS, or PI System. However, it would be useful for the exact same streams and assets that would be created on those remote endpoints ...
Jason Lu about 2 months ago in Edge Data Store / General 0 No status

Update DataCollectorHealth and StorageHealth Asset type

EDS is pushing at least 2 Health assets (StorageHealth & DataCollectorHealth) with DeviceStatus stream but this stream is not inside the asset type as streamReference. So we are not able to use this stream to map into the Asset Status. Asset S...
Guest 4 months ago in Edge Data Store / General 0 No status

Provide GUI for Configuration

Edge Data Store would require a GUI for configuration and health status to work more efficiently to set it up with too many efforts. The GUI should allow to set up the connection to the Data sources of the included PI Adapters, provide OPC UA brow...
Guest about 2 years ago in Edge Data Store / General 0 No status

Support System States for the Adapter for Azure Event Hubs

The data passed through the Adapter for Azure Event Hubs can be very dynamic in its configuration. It would be useful to be able to send system states to indicate bad data, and possibly the nature of that bad data. In the same way that interfaces ...
Mike Horrocks about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Azure Event Hubs 2 No status

Allow EdgeCmd to set null or empty string parameter values

As per KB000042993, setting parameters with EdgeCmd that are <null> or "" (empty string) is not possible. Instead the JSON configuration file must be created and used in place. It would be more intuitive if executing commands such as: edgecm...
Mike Horrocks over 1 year ago in Edge Data Store / General 1 No status

Defining "Scan Class" and "Poll" Capabilities in Aveva Adapter for Azure Event Hubs

Define the "Scan Class" and "Poll" capabilities in the Aveva Adapter for Azure Event Hubs, similar to the functionality available in the Interface. Ensure the ability to manually select a "Scan Class" for PI Points and define it as "Poll".
Guest about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for Azure Event Hubs 0 No status

Conditional Data Egress for Edge Data Store

Scenario: In a remote monitoring scenario, Edge Data Store is collecting data through OPC UA or ModbusTCP with a certain sampling rate (assumingly 1s). For normal operations, EDS shall egress only an aggregated one minute value of all analogue str...
Guest about 2 years ago in Edge Data Store / Egress 0 No status

Add a new diagnostic: the IO rate in bytes or megabytes

The current IO rate diagnostic is helpful, but it only shows events per second. For sites who need to manage their bandwidth and make decisions about how much to buy and support from remote sites, it's very important to be able to monitor exactly ...
Daniel Lopez over 1 year ago in Edge Data Store / Egress 0 No status

Data Retention configuration for EDS SDS

We have no information regarding data retention. This could be clarified. Data retention should be better configurable as of now, only the stream size can be configured just by estimation. Provide a sizing and calculation tool for Edge Data Store ...
Hans-Otto Weinhold about 2 years ago in Edge Data Store / Historian 0 No status

Addition of substitution parameters in DefaultStreamIdPattern -> specify a ValueField for it to read from

People wanting to use a single EventHub and Container holding events from many sources with common attribute naming. Want to be able to differentiate the naming of the pi tags based on source. Being able to substitute a unique source identifier (s...