To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 14 of 5194

Allow AVEVA Adapter for Modbus TCP to collect data on INT64 and UINT64 registers

Certain equipment is providing energy data under INT64 or UNIT64 register types. However, the Adapter currently only supports FLOAT64, which is not compatible. We want to be able to configure the Adapter for Modbus TCP to collect data on INT64 and...
Alexa Derago 3 months ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 Future consideration

Add the ability to multi-select and move display columns in Asset Filter Search, Explore Events, and Compare Events

Currently, only a single item can be selected and moved (or deleted) in the "Attributes to display" list in Asset Filter Search. An analagous behavior exists in the "Columns to display" list in Explore Events, and Compare Events. For each of these...
Guest over 3 years ago in AVEVA™ PI DataLink™ / Task Pane 3 Declined

Improve Visibility for Automatic Task Pane

As user of PI DataLink, I would like the Automatic Task Pane to highlight the referenced cells in different colours that the functions (e.g. Sampled Data) are using. It helps to improve visibility and reduce confusion.
Willy Seah 7 months ago in AVEVA™ PI DataLink™ / Task Pane 0 No status

Calendar/Timestamp Control Can Be Used to Help Populate Time

Calendar/Timestamp (DatePicker) control can be used to help populate time fields. Populating the cells might also be a nice enhancement. Note: This was previously Enhancement 17311OSI8.
Guest over 3 years ago in AVEVA™ PI DataLink™ / Task Pane 0 Declined

Implicit Intersection Operator @ prevents PI DataLink from parsing its formula

PI DataLink side panel should be able to parse Implicit Intersection Operator @ so formulas can be edited, when inserted by Microsoft Excel with Office 365,
Guest over 3 years ago in AVEVA™ PI DataLink™ / Task Pane 0 No status

Expand Healthpoint (Device Status) Information of the PI Adapter for Modbus TCP from Component to "Device" Level

When configuring PI Modbus TCP adapter you first define a component level and under this type you define your different devices/machines/sensors. In case of a broken connection to one of the devices the healthpoints currently only deliver the stat...
Mario Amrhein about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Support for "RTU over TCP" for Modbus Adapter using MBAP header

Challenge: Today, the PI Adapter for Modbus TCP does not natively support " RTU over TCP". It does support Modbus TCP, so as long as the "bridge" properly converts Modbus RTU to Modbus TCP (including the MBAP header), it should work fine. If the b...
Hans-Otto Weinhold about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Asset Filter search unusable if Office theme is set to Dark Gray. Attributes section shows up in white font on white background.

To make it usable.
BruceMcCamant over 2 years ago in AVEVA™ PI DataLink™ / Task Pane 0 No status

Allow multiple references to holding register for bit extraction

Given a 16bit integer holding register, in certain instances we only care for specific bits rather the integer value. Using the bitmap allows the selection of those specific bits but you can only reference the register once. i.e. In data selection...
Matthew Kishe almost 3 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 8 Future consideration

Datalink - Root Path should allow to specify multiple Data Archives

Currently, the Root Path field of Datalink can be pointed to a single cell to retrieve the name of the Data Archive where the tag resides. It is not possible to specify an array of cells, as only the first Data Archive will be considered. There ...
Guest over 3 years ago in AVEVA™ PI DataLink™ / Task Pane 0 Declined