Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

AVEVA™ PI Server

Audit trail logs activation and de-activation

One of my customers requirements change regarding Audit Trail: it's required that If an Audit trail can be turned off by anyone, then it should be detectable. Right now, turning off an Audit trail requires a system restart which is highly detectab...
Erik Prins 23 days ago in AVEVA™ PI Server / General No status

Automatically Adjust Attribute Unit based on Attribute Value (or apply engineering notation)

In PI AF, implement a dynamic mechanism that makes very large (or very small) values readable and quick to understand. Example: If I have an attribute "Bytes Allocated" which has a unit of bytes (B), and a value of 228839424 B, I want AF to displa...
JD Rogers 10 days ago in AVEVA™ PI Server / Asset Framework (AF) No status
410 VOTE

Extensible analytics

As a process engineer I would like to be able to integrate complex specific calculations, such as from a 3rd party analytics engine, so that I can use the Asset Analytics and its context with all the available data and scheduling to run those with...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations No status
235 VOTE

Event Frame End Trigger Time True Functionality

As a user of event frames, I would like the ability to be able to set a time true condition for the end trigger of an event frame analysis, similar to how this functionality is available for the start trigger
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations No status
222 VOTE

Allow substitution parameters to be used in the SELECT and FROM clauses of the TableLookup Data Reference

As a user, I would like TableLookup Data Reference to be able to use substitution parameters to specify the column name(s) and table name for the SELECT and FROM fields respectively. This would allow for the use of attribute values like those from...
Guest over 3 years ago in AVEVA™ PI Server / Asset Framework (AF) No status
208 VOTE

Automatic Recalculation of Event Frame in PI Analysis

As a user, I would like to have the option to automatic recalculation of event frame for out-of-order input events in AF analysis. The option is available for expression analysis in PI Analysis  2017 R2 but not for event frame generation anal...
Willy Seah Wei Liat over 3 years ago in AVEVA™ PI Server / Analytics & Calculations No status
200 VOTE

Add more advanced string handling functions to the String Builder data reference

I would like to use some more advanced string functions such as Split, Len (string length), and even regex filtering to allow more fine grained control of how some input strings (such as attribute values or substitution parameters) are manipulated...
John Messinger over 3 years ago in AVEVA™ PI Server / Asset Framework (AF) No status
194 VOTE

Filter expression for inputs to a Rollup

As a user configuring a Rollup analysis, I want to be able to apply a filter expression on the inputs so that the Rollup only includes inputs that satisfy a condition. Note: This was previously Enhancement 114349.
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations No status

Admin Option to block check-in of linking an Analysis output to a Static Attribute

It is easy for AF Users to create a new attribute with Data Reference = None (aka Static Attribute) but then assign an analysis to update its value later. When this happens, all updates to the attribute are stored in table FindChanges_AT which can...
John Alessio 3 months ago in AVEVA™ PI Server / Analytics & Calculations No status
162 VOTE

Attribute UOM Substitution Parameter

If you have a PI Point attribute with auto tag creation and you want the attribute UOM and PI Point engunits to match, you have to define it twice; once in the attribute UOM field and a second in the attribute configuration string, e.g. engunits=m...
Guest over 3 years ago in AVEVA™ PI Server / Asset Framework (AF) No status