To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 52 of 5197

Asset Comparison Table: Add Child Attribute as Column

Currently, this can be accomplished by organizing you AF structure with rows as element names (assets) and columns as attributes using an Asset Comparison Table. I would like to see OSI Take the next step to generalize the asset table to be able t...
Guest over 3 years ago in AVEVA™ PI Vision™ / AF Integration 0 Declined

Show all AF databases used in PI Vision displays

Show the AF databases used by Pi Vision displays so users can verify that Displays will not break in case they need to delete or rename AF databases
Guest over 3 years ago in AVEVA™ PI Vision™ / AF Integration 1 No status

PI Vision Analysis Status Accessible as AF Tag (or PI Tag)

It would be useful to be able to get the analysis status for an element into either an AF tag or a PI Tag. Reason for this is I have a set of traffic lights that monitor certain statuses of tags, and if the analysis is off/failed then I can handle...
Guest over 3 years ago in AVEVA™ PI Vision™ / AF Integration 0 No status

Support for "RTU over TCP" for Modbus Adapter using MBAP header

Challenge: Today, the PI Adapter for Modbus TCP does not natively support " RTU over TCP". It does support Modbus TCP, so as long as the "bridge" properly converts Modbus RTU to Modbus TCP (including the MBAP header), it should work fine. If the b...
Hans-Otto Weinhold over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Allow multiple references to holding register for bit extraction

Given a 16bit integer holding register, in certain instances we only care for specific bits rather the integer value. Using the bitmap allows the selection of those specific bits but you can only reference the register once. i.e. In data selection...
Matthew Kishe almost 3 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 8 Future consideration

Automatically grey-out or hide attributes that are not configured well

It would be great if Attributes in AF that are not configured well (with errors) (AF.jpg) were automatically greyed-out or hidden in PI-Vision (Vision.jpg).
Guest over 3 years ago in AVEVA™ PI Vision™ / AF Integration 0 Declined

Calculation for futur PI tags or PI AF attribute

Hi. I'm working with forecast data and so, using PI tags as future data instead of real-time data. If I want to display my forecast into a PI Vision screen, I need to feed the period from *-5d to *+3d. And it works for the PI tags. But it doesn't ...
Guest over 3 years ago in AVEVA™ PI Vision™ / AF Integration 0 Declined

In a table be able to filter items all assets except ones with a value of  "No Data" regardless of their data type in AF such as double.

In a table be able to filter items all assets except ones with a value of  "No Data" regardless of their data type in AF such as double.
Guest over 3 years ago in AVEVA™ PI Vision™ / AF Integration 0 Declined

Error message should be generated for the Modbus request time out

After request time out, Modbus adapter should generate an error as time out after specified duration set by user.
Guest almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Accept HEX numbers for Register offsets in data selection

Most modbus equipment providers provide information using registers in Hex format i.e. 0x0000 ~ 0xFFFF. It would be nice if the offset could accept this to avoid error in conversions HEX to DEC. Would make things alot more seamless/easier.
Matthew Kishe almost 3 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 Future consideration