To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

URL Parameters for Ad Hoc Trend properties

Configure properties of Ad Hoc trends using URL parameters. For example, add "&backgroundcolor=white" or "&multiplescales" and other parameters to set Trend properties that are otherwise only set by selecting "Format Trend".
Guest about 4 years ago in AVEVA™ PI Vision™ / Ad Hoc Analysis 3 Declined

Make the results of the PI Vision Calculations reusable

Example: Calc1 = a * b Calc2 = Calc1 + c
Guest about 4 years ago in AVEVA™ PI Vision™ / Ad Hoc Analysis 2 No status

Design some UI for PI Adaptors

Design some UI for PI Adaptors, so it will be user friendly to configure the data source or data reading configurations etc. It is really hard to configure or troubleshoot an issue in PI Adaptor without Proper UI.
PradeepKumar Logandurai almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 2 No status

Allow AVEVA Adapter for Modbus TCP to collect data on INT64 and UINT64 registers

Certain equipment is providing energy data under INT64 or UNIT64 register types. However, the Adapter currently only supports FLOAT64, which is not compatible. We want to be able to configure the Adapter for Modbus TCP to collect data on INT64 and...
Alexa Derago about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 Future consideration

Enable AVEVA Adapter for OPC UA to work with OPC UA Servers that only allow Dynamic Addressing and Virtual Browsing

Some OPC UA Servers have the concept of Dynamic Namespace Addressing and Virtual Browsing. The UA Nodes do not exist in the OPC UA Address Space. Nodeids are created\added to the Address Space only when a Client makes a request for the NodeIds thr...
Vaskar Dahal 8 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Configuration reconnection (retry) time on the adapter

OPC UA adapter takes 5min by default to reconnect to a load balanced PI Web API pair which failed over.
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Allow Adaptors to run in Docker

Allow Adaptors to run in Docker. This would ease the roll-out and management of adaptors. Also new Cisco switches now allow Docker instances on the switch, limiting the need for extra hardware.
Erik Prins over 2 years ago in AVEVA™ Adapters / General 2 Already exists

Custom Top/Bottom for Digitals on Vision Trends

It would be useful to allow digital tags or attributes on a trend in PI Vision to have custom limits set for the Top and Bottom of the trend. It appears that in PI Vision 2022 that the only options for Top/Bottom settings on a trend are the availa...
Justin Jackson almost 4 years ago in AVEVA™ PI Vision™ / Ad Hoc Analysis 3 No status

Asset Comparison: Trend with multiple elements with specific attributes

Testing Coresight 2016. After searching for all the elements I want to display on one graph, I want to be able to select the attributes I want to display. Currently, can only drag all the elements onto the display, which creates a trend with all t...
Guest about 4 years ago in AVEVA™ PI Vision™ / Ad Hoc Analysis 5 No status

Adhoc Trends be able to change trace colors

Be able to change trace colors on adhoc displays, this would be useful where i need to be able to show upper and lower limits in a different color (ie red, yellow) to the process value (ie cyan) the standard colors dont reflect the alarms levels v...
Guest about 4 years ago in AVEVA™ PI Vision™ / Ad Hoc Analysis 0 No status