To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Analytics / Calculations

Calculated tags present value error

For calculated tags when being trended for more than ~12 hours time frame, the trend works fine except for the live present value, the calculation can be completely off. See attached screenshot for an example, where several tags are checked whethe...
AbdulRahman.Maskari 11 months ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

Remove arbitrary distinctions between AF points and PI points

Currently, Expressions like TimeGE which require two time contexts to evaluate only work with PI points, and not AF points. This restriction is arbitrary and does not appear to be documented anywhere. Unless documented, this should be regarded as ...
Kevin Wood 12 months ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

Add the function/calcultion of "Moving Average" for PI Tags

The ability to create an average calculation is within PI Vision, but it doesnt do moving average. You can set custom timing intervals (eg. every 5 min etc.) but what about a 5 min moving average that has a continuou data points for a trend. A wor...
Mitchell Davidson almost 4 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

Make PI Vision Calculation not affected by PI Point or AF Attribute renaming

When a PI point is renamed, any symbols that reference it directly continue to work. However, calculations that depend on the renamed PI point stop functioning. Please update the calculations so they remain functional even after PI points or AF at...
marc.cote 7 months ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

Possible to use a Calculated variable into a new Calculated value like a "Tag"

No description provided
Guest almost 4 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

Rate of change calculation is required for analysing points

Rate of change calculation is required for analysing points, especially steam parameters like temperature and pressure. This is required for fatigue analysis. For a selected time frame, the following four calculations will be required: 1) Maximum ...
AK about 3 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

How to built the PI vision calculate function for pump running time

Dear All, I need to built the calculate function in PI Vision That to calculate the pump running time When pump start, start counting time (in hours) until stop. After stop time must be reset to 0
DUONG PHAN almost 2 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

Time range configurable to attribute value

Allow the time range (either start time or end time or both) in Pi Vision to reference an attribute value. This would allow data to dynamically update according to an event. For example, I want to see a list of batch information (start time, end t...
Guest about 2 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

AVEVA PI Vision Trend should have the option to return archived values rather than the interpolated values based on the number of intervals in the trend depending on pixel width

PI Vision Calculation data in Trends are not accurately showing outlier values depending on trend sizing. The discrepancies are caused when the width/pixel size of the display varies between trend symbols, which affects the intervals used for eval...
Dong Yeow Wong almost 3 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 2 No status

UOM and Display digit options for calculation in vision

Similar to point builder, there should be an option for putting Eng Unit and Display digit within vision.
Piyush Dubey over 2 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status