Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 218 of 5259

PI Adapter for OPC UA should send the previous value when it has been with the same value for a long time

"This enhancement request proposes a solution to address the issue of data interpolation between two values far apart in time in adapter data collection. The suggestion is to include the value right before the new data point, ensuring the fidelity...
Fabio Dani over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Enable Adapter for OPC UA to use the Pub/Sub method

Pub/Sub is proposed to be a more efficient and scalable method of transferring data using OPC UA. Allowing the adapter to access data in this way would increase the options for data collection, and allow the OPC UA adapter to be used in many more ...
Mike Horrocks over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

API to check Adapter buffer statistics

We can check buffer statistics with PI Buffer subsystem (pibufss -cfg, qs) and also with PI Connector/Relay, to verify whether Buffer is healthy, events in queue and etc.Adapter does not has any API to check this.
Ee Sheing Lee over 2 years ago in AVEVA™ Adapters / General 0 No status

Add parameter "Max Monitored Items per Subscription"

The connector for OPC UA includes a parameter “Max Monitored Items per Subscription”, which is very helpful in managing UA servers which may have limits on the maximum items per subscription. This parameter needs to also be available in the adapters.
sahilp about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 3 Future consideration

Add the option "Ignore Bad_WaitingForInitialData Status"

In the connectors there was the option "Ignore Bad_WaitingForInitialData Status", as described here. For gen 1 there was a need to edit the config files directly, and in gen 2 the option was integrated into the UI. Instead for the adapter I recent...
sahilp over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Make the Format Trend Menu Available for EF Comparisons

Add the ability to use the Format Trend function to the Event Frame Comparison Tool.
Guest over 3 years ago in AVEVA™ PI Vision™ / Events (EF) 0 Declined

Event Details Hyperlink Non-Numeric Tag in Trend

As a user of PI Vision, I would like to be able to view the digital tags associated with a notification on a trend when I click the Event Details Hyperlink on my Notification email. Right now only numeric attributes are can be added to the trend b...
Guest over 3 years ago in AVEVA™ PI Vision™ / Events (EF) 2 Declined

Have the event frame view as a symbol

Having the event frame view as a separate type of graph, means that it is not possible to add in contextual value or to set up comparisons very easily. It would be great to have the an event view symbol. It would be configured similar to how colle...
Guest over 3 years ago in AVEVA™ PI Vision™ / Events (EF) 0 Declined

apply event time range to pi vision display to show time before and after event.

We have events of short duration and often use the "apply time range" option from the events table or events search in Pi Vision. We then have to manually adjust the time frame in PI Vision to be able to see a wider time range and understand what ...
tdeibe01 over 3 years ago in AVEVA™ PI Vision™ / Events (EF) 0 No status

Show & enter comments from the Event Table (with pencil & pop-up like reason codes

Realizing that comments can be of indeterminate length and number, the table could just indicate the presence of comments and the pop-up show the comments.
Martin Bryant over 3 years ago in AVEVA™ PI Vision™ / Events (EF) 0 No status