To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 33

Enhance Visibility of Event Frame Generator/Batch Interface History Recovery Status

Currently when running any event frame generator interface (EFGen, PIFTBatch, etc.) in history recovery mode, there is no way to monitor progress of the actual history recovery. The only way to determine status is to check message logs periodicall...
Guest over 3 years ago in PI Interfaces / Batch Interfaces 0 No status

Enhance how batch interfaces write to the message logs

Batch interfaces should write their messages to the message logs using the Source1 and Source2 fields just like UniInt based interfaces. Currently, batch interfaces leave these 2 fields blank. Source1 should contain the process name or similar and...
Guest over 3 years ago in PI Interfaces / Batch Interfaces 0 No status

Create 'Close Event Frame delay' setting

When you create PI Point Data Reference attributes in event frame templates that are used by PI Batch Interfaces, the PI Batch Interface will be responsible for resolving and capturing this PI Point data as soon as it closes the corresponding even...
Rafael Batista 11 months ago in PI Interfaces / Batch Interfaces 0 No status

Batch interface to AF connection health monitoring tag

Having a health tag for batch interfaces which monitors the connection status between the interface and its corresponding AF server. This way, users can be informed if there are any issues with the interface creating event frames on AF.
Guest over 2 years ago in PI Interfaces / Batch Interfaces 0 No status

PI EMDVB - Set Procedure start time to match first Unit Procedure start time

Currently, when an operator adds a new batch to the DeltaV Batch List, that "creation" action starts a new EF Procedure. But the batch might sit in that list for a long time before the Unit actually starts processing it. This leads to a huge empty...
Guest over 1 year ago in PI Interfaces / Batch Interfaces 0 No status

Email Report out

auto generated emails at certain intervals (every 8 hours) that send out uptimes, case counts, selected data points which can be collected and sent to a distribution list.
Guest over 3 years ago in AVEVA™ PI Vision™ / Notifications 0 No status

A test Multi state button some of our displays have 100S would be nice to test the functionality even set limits so that they go off correct

Functionality Button even set to limits to see if the multistate on that page are functional
Guest over 3 years ago in AVEVA™ PI Vision™ / Notifications 0 No status

Improve the recovery process for long EFGEN batches

Currently if EFGEN is configured to evaluate PI Points at the event end, long batches require recovery start time to be set before the start of the batch. This leads to a long recovery process as many completed batches will be evaluated again.
Guest over 3 years ago in PI Interfaces / Batch Interfaces 0 No status

PI EMDVB Interface - Allow to retrieve "description" column content from SQL DB

The interface can retrieves Report events [Event,value="Report"]. Within these events, [Descript] - parameter returning "category" from SQL database. We could not retrieve "description" column contents from the SQL DB [BReportEvent] table. See cas...
Guest over 3 years ago in PI Interfaces / Batch Interfaces 0 No status

Revive PI EMDVBCS support to <Description> tag

Customer has been using the description tag for the Operation (OP) for the instances that get sent to OSI PI using EMR.WF.PI.Task.This atribute gets populated while they are using PI EMDVBCS v4.1.9.3669. However when they upgraded to v4.3.1.24 - t...