To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 20 of 5197

Suppress the creation of "Status Flag" PI Points

The end-user would like to suppress the creation of the "Status Flag" PI Points, as they wish to keep their point count to a minimum due to the license-enforced point limit.
Guest over 3 years ago in PI Connectors / PI Connector for BACnet 0 No status

Program objects (BACnet object type 16) also bought through by the connector

The program object description is often very useful to understand what the various object instances relate to. At our site the description holds the Asset designation and that would allow correct assignment of the analogue and binary object instan...
Guest over 3 years ago in PI Connectors / PI Connector for BACnet 0 No status

Big Brother

Audible alarms that can be configured in the multistate menu w/ the ability to upload custom bytes. The ability to program a point to trigger an event that would wirelessly send alerts to a specified user or group (email or data text alert)
Guest over 3 years ago in AVEVA™ PI Vision™ / Notifications 0 No status

Log device information when the Connector receives errors from a device

Currently the Connector logs when it receives errors, but does not print information that can be used to determine which device is reporting the errors. We currently need to perform a wireshark trace to look at the individual packets to determine...
Guest over 3 years ago in PI Connectors / PI Connector for BACnet 0 No status

Distribute-Broadcast-To-Network broadcast for Discovery Tool and Connector

When running the discovery tool from a subnet with no BBMD to query BACnet devices on a separate subnet, it seems like the auto discovery tool is seen as a ‘foreign device’, so the devices do not respond correctly. When analyzing a Wireshark trac...
Guest over 3 years ago in PI Connectors / PI Connector for BACnet 0 No status

Allow the BACnet Connector to handle responses with an LVT that does not match the request

Currently the BACnet Connector expects devices to respond with the same "Length Value, and Type" (LVT) value as the request. When this occurs the BACnet Connector cannot parse the data in the response. For example: Request from Connector, LVT=1 Re...
Nico Cha almost 2 years ago in PI Connectors / PI Connector for BACnet 0 No status

Enable / Disable Notification Rules

As a PI Unser, i want to See if a Notification is enabled or not
meierke1 over 3 years ago in AVEVA™ PI Vision™ / Notifications 0 Declined

Email Report out

auto generated emails at certain intervals (every 8 hours) that send out uptimes, case counts, selected data points which can be collected and sent to a distribution list.
Guest over 3 years ago in AVEVA™ PI Vision™ / Notifications 0 No status

A test Multi state button some of our displays have 100S would be nice to test the functionality even set limits so that they go off correct

Functionality Button even set to limits to see if the multistate on that page are functional
Guest over 3 years ago in AVEVA™ PI Vision™ / Notifications 0 No status

Increase the maximum timeout for the BACnet Discovery Utility with the PI Connector for BACnet

If a user has many BACnet devices/objects discoveries can take some time. Since the BACnet Discovery Utility has a maximum timeout of 240 seconds, this utility can cannot be used in these scenarios and manual creation of the csv is required which ...