Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

displayname/localname for identifier that excludes namespace and data type

Example: OPC UA Server 'Name': 2.0:W-HVAC-AC-1-IO!Wtot Namespace: 2 Datatype: 0 Identifier: W-HVAC-AC-1-IO!Wtot OPC UA Server 'DisplayName': W-HVAC-AC-1-IO!Wtot OPC UA Adapter {Identifier} returns: 2.0:W-HVAC-AC-1-IO!Wtot Required stream name: W-H...
Guest about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Allow EdgeCmd to set null or empty string parameter values

As per KB000042993, setting parameters with EdgeCmd that are <null> or "" (empty string) is not possible. Instead the JSON configuration file must be created and used in place. It would be more intuitive if executing commands such as: edgecm...
Mike Horrocks about 2 years ago in Edge Data Store / General 1 No status

Enable Adapter for OPC UA to use the Pub/Sub method

Pub/Sub is proposed to be a more efficient and scalable method of transferring data using OPC UA. Allowing the adapter to access data in this way would increase the options for data collection, and allow the OPC UA adapter to be used in many more ...
Mike Horrocks about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Is there a way of enabling a confirmation window when modifying AF attributes or PI Points?

Suggestion:Would it be possible, in AF revisions and even in tag revisions via PI-SMT, to have a window open whenever any change is made, requesting the reason for the change? And would this information be stored somewhere with the attribute path,...
Ana Izzi 9 months ago in Developer Resources / General 0 No status

Support for the Galileosky Protocol

Need an option for direct integration of Galileosky GPS tracking devices with the AVEVA PI System without third-party middleware. The devices primarily use the proprietary Galileosky binary protocol (TCP-based, port 20332 by default) for real-time...
Mohammed Qasim Asghar 9 months ago in AVEVA™ Adapters / New Connectivity 0 No status

Improve throughput

I am not sure if this is a limitation connected to the OMF, WebAPI, or https itself, but in the manual it is given that the maximum message size is 192KB. I am aware that compression is recommended and applied by default by the adapters. For the r...
sahilp about 3 years ago in Developer Resources / Open Message Format (OMF) 0 No status

Permit non-protected references

The secrets references is a very useful addition but they are only permitted for "protected" parameters. It would be useful to also create references for non-protected parameters. Using references for non-protected parameters would help with creat...
Mike Horrocks about 3 years ago in AVEVA™ Adapters / General 1 No status

Add feature for PB to PI Vision Migration Utility to use local folder if target linked display cannot be resolved.

As PI Vision admin I have to migrate ProcessBook displays from several users throughout the company. There is no easy way to open each display and check if the target display path is valid and fix via PI Processbook Support Tool before running the...
Alex Santos about 3 years ago in AVEVA™ PI Vision™ / ProcessBook Migration 0 No status

PB to Vision Display Migration Utility: Add support for UNC style file paths

Some organizations are discontinuing the use of mapped drive letters since they are a known cyber attack vector and are instead using UNC file paths (eg. \\fileserver\share) to access network shares. There is no way to navigate to a network locat...
Guest about 4 years ago in AVEVA™ PI Vision™ / ProcessBook Migration 0 No status

Better migration of symbol library symbols using the PI ProcessBook to PI Vision Migration Utility

The color of some symbol library symbols is different in PI ProcessBook and PI Vision after migrating PI ProcessBook displays to PI Vision. It would be nice if the color did not change, or if the Migration Utility allowed users to choose the desti...
Jaedyn Larson about 4 years ago in AVEVA™ PI Vision™ / ProcessBook Migration 0 No status