To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 481 of 5222

Setting of parameters k and w for IEC 60870-5-104

Parameters k (Maximum number of outstanding I format APDUs) and w, cannot be adjusted, while vendors recommend customers to set it to k=12 and w=8
Guest over 3 years ago in PI Connectors / Other specific PI Connector 1 No status

PI Connector for Modbus TCP - include option to configure response data byte size by register type.

Certain RTUs limit the number of Boolean/Discrete values they return independently of the number of floats they return. The PI Connector for Modbus has a configuration option for “Maximum Response Data Bytes” but it applies to all register types. ...
Guest over 3 years ago in PI Connectors / Other specific PI Connector 0 Declined

X509 User Token Policy

Allow future releases of the OPC UA Connector to support user authentication via certificate or IssuedToken instead of only through user/password or anonymous connection.
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 2 No status

Possible to use a Calculated variable into a new Calculated value like a "Tag"

No description provided
Guest over 3 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

EDS: OPC DA Connector

Ability for OPC DA connector to write data to Edge Data Store.
Guest over 3 years ago in Edge Data Store / Ingress 1 Declined

Scan only when the data folder changes

Specifying the scan time seems unnecessary. Instead, the PI Connector for UFL should only scan the data folder if a change to the data folder's contents is detected. Surely some sort of event listener can be set up to achieve this?
Kenneth Barber over 3 years ago in PI Connectors / PI Connector for UFL 0 No status

PI Connector for SKF Vibration Monitoring

Develop a connector for SKF Vibration Monitoring
Guest over 3 years ago in PI Connectors / New PI Connector Request 1 No status

Time range configurable to attribute value

Allow the time range (either start time or end time or both) in Pi Vision to reference an attribute value. This would allow data to dynamically update according to an event. For example, I want to see a list of batch information (start time, end t...
Guest over 1 year ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

Rate of change calculation is required for analysing points

Rate of change calculation is required for analysing points, especially steam parameters like temperature and pressure. This is required for fatigue analysis. For a selected time frame, the following four calculations will be required: 1) Maximum ...
AK over 2 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

Make the PI Data Collection Manager more user friendly for setting up the connector and Relay

Customer from case 01234736 has mentioned that it can be confusing having the Connector Administration and PI Data Collection Manager have the options to modify and configure the PI Connectors 2.x. For example, when configuring the Data Source, yo...
Guest about 1 year ago in PI Connectors / General 0 No status