Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Classic Mode for Adapters

One of the big issues we have with adapters (outside of the lack of write capability) is not having the same control over creating and editing tags that we have with PI interfaces. As we talked about the adapter automatically creates PI tags or us...
Brian Rock over 3 years ago in AVEVA™ Adapters / General 5 Future consideration

Configuration reconnection (retry) time on the adapter

OPC UA adapter takes 5min by default to reconnect to a load balanced PI Web API pair which failed over.
Guest about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Enable Multiple PI to CONNECT agents for one PI Data Archive

Aside from our main AF Server setup used for numerous use cases like energy, OEE, etc, we have created a second environment of AF Server / AF Analysis / SQL Server to isolate the monitoring of a critical process. We are still making use of a singl...
Christian Leroux about 3 years ago in PI to CONNECT / General 0 No status

processor rate(s) for Processor properties of Modbus Adapter Service Health

Visualize and understand usage when trended with other diagnostic properties.
Guest 2 months ago in AVEVA™ Adapters / General 1 No status

OMF Egress health to include stream count

Validate stream count for scenarios where there are multiple Components
Guest 2 months ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Table: Support Different Table Styles

Similar to tables in Word / PowerPoint, support several different styling options for tables. Additionally, support the ability for a user to style a table exactly how they want it (with background fill colors, text colors, etc.).
Guest almost 4 years ago in AVEVA™ PI Vision™ / Symbols 0 Declined

XY Plot: Logarithmic scales for both axes

It would be useful to be able to implement a logarithmic scale to either/both axes of xy plots.  Specific use case: Diagnose well conditions in real time by looking at conditions based on elapsed time since an event frame.  To be able ...
Guest almost 4 years ago in AVEVA™ PI Vision™ / Symbols 1 Declined

Add rotation formatting to Value

Allow rotating the Value symbol in the same way as the Text symbol can be rotated.
Jørgen Foss almost 4 years ago in AVEVA™ PI Vision™ / Symbols 4 Declined

Allow for PI Vision Attribute Collection Filter to Filter on Digital States

As a PI Vision user, I would like to be able to perform an attribute filter on my collection symbol to filter out attributes with certain digital states so that I can have a collection which does not contain assets with an attribute which has a va...
Guest almost 4 years ago in AVEVA™ PI Vision™ / Symbols 0 No status

Trend: Time Range: Duration and Offset - Add option to support start time

Currently the Trend object's Time Range has a Duration and Offset option which will take the End Time of the display and a specified duration for the trend's timerange. We need to have the ability to do the same based on the Start Time and a durat...
Guest almost 4 years ago in AVEVA™ PI Vision™ / Symbols 2 No status