Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

A Bulk Call for Last Values

A customer asks for a way to retrieve the last values of a group of streams in a single call.
Victor Zhang almost 3 years ago in Developer Resources / CONNECT data services API 0 No status

Adapter for OPC UA to support Global Discovery Server

Currently, to manage the OPC UA Server/Adapter certificate, we have to manually move the certificate or get the certificate trusted beforehand. This is expected for self signed Application certificate for both the Server and the Client (Adapter). ...
Ee Sheing Lee about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 2 Tell us more

PI Adapter for GE e-terrahabitat/HabConnect

We need a new robust product to support data transfer between GE e-terrahabitat/HabConnect and PI. This product would need to support the following: Highly available remote management/deployment multiple instances on a single node (to support larg...
GaryYegiazaryan about 3 years ago in AVEVA™ Adapters / New Connectivity 0 No status

Add the capability to create striplines on the trends.

Having the capability to add striplines to the trend feature could help indicate events that occur on the trends. For example, this could help identify what step or part of a process a batch is in when reading a temperature trend to help induce wh...
Guest over 2 years ago in AVEVA™ RtReports / Editor 0 No status

PI Adapter for OPC UA should send the previous value when it has been with the same value for a long time

"This enhancement request proposes a solution to address the issue of data interpolation between two values far apart in time in adapter data collection. The suggestion is to include the value right before the new data point, ensuring the fidelity...
Fabio Dani about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Support System States for the Adapter for Azure Event Hubs

The data passed through the Adapter for Azure Event Hubs can be very dynamic in its configuration. It would be useful to be able to send system states to indicate bad data, and possibly the nature of that bad data. In the same way that interfaces ...
Mike Horrocks over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Azure Event Hubs 2 No status

Improve the message for performing on demand History Recovery on datacollectionmode: "CurrentWithBackfill" and "CurrentOnly"

Running edgecmd to perform HR on demand on the datasource: datacollectionmode of Non HistoryOnly. will return the following error: Operation Failed: NotFound (404)Unexpected error: Unexpected character encountered while parsing value: 0. path '", ...
Ee Sheing Lee almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Resizing the Installation Complete and Installation Error Window

For users who are performing installations through the use of PI System installation kits they would like the ability to resize the Installation Complete (Installation Error) Window so that they can get all of the details on all of the modules of ...
Guest almost 4 years ago in AVEVA™ PI Server / Installation 0 Declined

Selectively install 32-bit versus 64-bit versions of PI programs

Currently, install kits such as those of PI DataLink, PI AF Client, PI API, PI SDK, PI OLEDB Provider, PI OLEDB Enterprise, and PI SQL Client always install both the 32-bit and 64-bit versions. Most of the time, one of these versions is unused and...
Kenneth Barber almost 4 years ago in AVEVA™ PI Server / Installation 3 No status

Ability to specify default AF database during installation of PI AF Client

Currently, the PI AF Client installation allows the user to select a default PI Data Archive and default AF server but not a default AF database. It would be nice, especially for silent installations, to be able to specify the default AF database ...
Guest almost 4 years ago in AVEVA™ PI Server / Installation 0 No status