To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 77 of 5194

EFGEN - Allow Active Point Trigger Based on Specific Value/Logic/Calculation

Using EFGen, currently an EF can only be triggered based on the zeroth state of the Active Point. This makes is impossible to trigger different events based on specific values of a single PI Tag. I am trying to implement a batch structure using ...
Guest over 3 years ago in PI Interfaces / Batch Interfaces 0 Declined

EMERSON PK based DCS - EMDVB Interface support

Emerson has a new PK Controller based DCS available (in lieu of full blown DeltaV). This new device is contained with OPC-UA and Batch Exec/Historian. We want support for the existing EMDVB interface to supply S88 based batches into PI Event Frame...
Guest over 3 years ago in PI Interfaces / Batch Interfaces 0 Declined

Add support for workgroups for PI Interface for Emerson DeltaV Syncade

Add support for workgroups for PI Interface for Emerson DeltaV Syncade
Alan Izar over 3 years ago in PI Interfaces / Batch Interfaces 2 Declined

Data Verification for the PI Interface for Emerson DeltaV Batch

Add a feature that performs a verification check of the data in PI against data in the DeltaV Historian and provide a report of any missing or mismatched data.
Guest over 3 years ago in PI Interfaces / Batch Interfaces 1 Declined

Enable the ability to use the UserInt1 to propagate PI to PI APS source tag name changes to the target if source collective Data Archive-level failover is configured

UserInt1 attribute contains source point ID. (Illegal configuration if source Data Archive-level failover is configured.) Source tag mapping by point ID is not compatible with Data Archive-level failover.
Guest over 2 years ago in PI Interfaces / PI to PI Interface 0 No status

Supress PI-APS messages for Error -2147220428: Failed to create point on server. [-10550] Tag Already Exists in Table

Seeing "information" messages in PI-SDK related to "Error -2147220428: Failed to create point on server. [-10550] Tag Already Exists in Table" which is irrelevant to see in the logs. If one source instance sending to multiple destination instances...
AshwinC over 2 years ago in PI Interfaces / PI to PI Interface 1 Future consideration

PI EMDVB - Set Procedure start time to match first Unit Procedure start time

Currently, when an operator adds a new batch to the DeltaV Batch List, that "creation" action starts a new EF Procedure. But the batch might sit in that list for a long time before the Unit actually starts processing it. This leads to a huge empty...
Guest over 1 year ago in PI Interfaces / Batch Interfaces 0 No status

PItoPI: Disabling Time adjustment

the ability to disable the timezone adjustment. currently we are calculating daily kpis on our global pi server. with PItoPI we are sharing it to the site pi-servers. so the daily kpi for e.g. 1st januar 2019 00:00AM sould alwas have that timesta...
MichaelHuber over 3 years ago in PI Interfaces / PI to PI Interface 1 No status

Batch Framework Interfaces - Allow creation of only the Event Frame levels that exist on data source

The BES/MES sometimes contains recipes with no Procedure, or even Unit Procedure. The Batch Framework Interfaces should allow the creation of only the Event Frame levels that exist on the data source. This would need to be enabled with an interfac...
Guest over 3 years ago in PI Interfaces / Batch Interfaces 1 Declined

Allow PI Interface for EMDVB to have the ability to define the source system Time/TimeZone offset.

PI EMDVB interface stops because of time difference between SQL and PI servers: "Error, SQL Server is ahead of PI Server more than 30 seconds, please adjust clocks. " That means we should adjust the (SQL server) DCS clock. However 30 seconds see...
Jose Sanchez Colunga over 3 years ago in PI Interfaces / Batch Interfaces 1 Declined