To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Batch Interfaces

Showing 28

Batch interfaces keeping merged child operation EventFrames open until the parent Operation EventFrame has been closed.

Currently for batch interfaces using the /MUP parameter, child operation event frames might be reopened and closed multiple times until the last operation event frame closes and the child event frame is closed for good. For example with UnitProced...
Guest over 1 year ago in PI Interfaces / Batch Interfaces 0 No status

PI EFGen 4.1+ has limited recovery capabilities

Up to PI EFGen 4.0, we were able to backfill OOO Event Frames by simply inputting the start and end time of the corresponding period. Since 4.1, this must be done in a per-event basis, since larger time ranges are modified so that RST matches the ...
Guest over 3 years ago in PI Interfaces / Batch Interfaces 1 No status

Have the FTB Interface support multiple stop events for Unit Procedures

There are instances where a batch must be manipulated creating two Unit Released events in the event file. The desired behavior for the PI FactoryTalk Batch Interface would be for the second end time to overwrite the first end time when data is be...
Guest 12 months ago in PI Interfaces / Batch Interfaces 0 No status

Have the FTB interface not truncate the trailing "-#" index (e.g. UnitProcedureName-1) at the end of a Unit Procedure

Some FactoryTalk batch processes have overlapping Unit Procedures with trailing indexes. Because the trailing index is truncated it results in overlapping Unit Procedures with the same name which are then merged. The desired behavior would be for ...
Guest 12 months ago in PI Interfaces / Batch Interfaces 0 No status

Have the FTB interface capture "Active Step Change Commencing" events as event frames

Some FactoryTalk batch processes require "Active Step Change Commencing" event to be part of the batch hierarchy however the PI Interface for Factory Talk Batch starts event frames only on [EVENT] = "System Message" or "State Change".
Guest 12 months ago in PI Interfaces / Batch Interfaces 0 No status

Batch Interface for Honeywell Experion

We are in need of a PI Batch/AF Events Interface to store data from Honeywell Experion Batch or Honeywell Procedure Analyst into PI Asset Framework.
Jürgen Schmidt over 3 years ago in PI Interfaces / Batch Interfaces 0 No status

Double check window required when deleting an instance in PI Event Frames Interface Manager

As a PI System Admin, I would like to see a confirmation window (acceptation pop-up message), when deleting Interface instances in PI Event Frames Interface Manager. This would minimize the deletion of the instances by error.
Guest over 3 years ago in PI Interfaces / Batch Interfaces 0 No status

Enhance Visibility of Event Frame Generator/Batch Interface History Recovery Status

Currently when running any event frame generator interface (EFGen, PIFTBatch, etc.) in history recovery mode, there is no way to monitor progress of the actual history recovery. The only way to determine status is to check message logs periodicall...
Guest over 3 years ago in PI Interfaces / Batch Interfaces 0 No status

Create 'Close Event Frame delay' setting

When you create PI Point Data Reference attributes in event frame templates that are used by PI Batch Interfaces, the PI Batch Interface will be responsible for resolving and capturing this PI Point data as soon as it closes the corresponding even...
Rafael Batista 10 months ago in PI Interfaces / Batch Interfaces 0 No status

Enhance how batch interfaces write to the message logs

Batch interfaces should write their messages to the message logs using the Source1 and Source2 fields just like UniInt based interfaces. Currently, batch interfaces leave these 2 fields blank. Source1 should contain the process name or similar and...