To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 19 of 5194

Log device information when the Connector receives errors from a device

Currently the Connector logs when it receives errors, but does not print information that can be used to determine which device is reporting the errors. We currently need to perform a wireshark trace to look at the individual packets to determine...
Guest over 3 years ago in PI Connectors / PI Connector for BACnet 0 No status

Distribute-Broadcast-To-Network broadcast for Discovery Tool and Connector

When running the discovery tool from a subnet with no BBMD to query BACnet devices on a separate subnet, it seems like the auto discovery tool is seen as a ‘foreign device’, so the devices do not respond correctly. When analyzing a Wireshark trac...
Guest over 3 years ago in PI Connectors / PI Connector for BACnet 0 No status

Allow the BACnet Connector to handle responses with an LVT that does not match the request

Currently the BACnet Connector expects devices to respond with the same "Length Value, and Type" (LVT) value as the request. When this occurs the BACnet Connector cannot parse the data in the response. For example: Request from Connector, LVT=1 Re...
Nico Cha almost 2 years ago in PI Connectors / PI Connector for BACnet 0 No status

Test Modbus Serial interface with newer Operating Systems

Currently the Modbus Serial interface supports Windows 7 as the latest possible operating system. Please test the Modbus Serial interface version 4.0.7.61 with operating systems such as Windows 10 or 11. Or release a new Modbus Serial interface th...
Rachel Morgenroth about 3 years ago in PI Interfaces / PI Interfaces for Modbus 0 No status

Provide support for Modbus function code 20

Provide support for Modbus function code 20
Guest over 3 years ago in PI Interfaces / PI Interfaces for Modbus 0 No status

POINDexter app be modified such that addresses beyond 64000 can be used

POINDexter application be modified such that addresses beyond 64000 are able to be ‘tested’ / polled, rather than having to configure a tag to read those registers
Guest over 3 years ago in PI Interfaces / PI Interfaces for Modbus 3 No status

Increase the maximum timeout for the BACnet Discovery Utility with the PI Connector for BACnet

If a user has many BACnet devices/objects discoveries can take some time. Since the BACnet Discovery Utility has a maximum timeout of 240 seconds, this utility can cannot be used in these scenarios and manual creation of the csv is required which ...
Nico C almost 2 years ago in PI Connectors / PI Connector for BACnet 0 No status

Interface for Modbus output to 4byte (32bit) registers

There are Modus supporting devices that feature 32bit single registers (e.g ROC800-Series). PI Interface for Modbus should be updated to have support to output to these 4byte (32bit) registers. Currently PI Interface for Modbus only has support f...
Guest over 3 years ago in PI Interfaces / PI Interfaces for Modbus 2 No status

Support Modbus device failover

Enhance the interface to support redundant Modbus devices with different network cards/IP addresses. The controllers would publish a status update on the active device, and the interface should request data from it accordingly.
Guest over 3 years ago in PI Interfaces / PI Interfaces for Modbus 0 Declined