Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 380 of 5192

Custom Edit Value Mode

Provide an opportunity to customize the edit Value Mode (minus 1 second : for instance 0.5 second or year)
Lebretonp over 3 years ago in PI Integrators / AVEVA™ PI Integrator for Business Analytics 1 No status

Allow streaming view for Event Frames in the PI Integrator for Business Analytics

It would be useful to be able to stream Event Frames via the PI Integrator for BA so that the associated and aggregate data for events can be used in targets. This opens the possibility of using Event Frames to identify specific situations, gathe...
Guest over 3 years ago in PI Integrators / AVEVA™ PI Integrator for Business Analytics 0 No status

Possibility to backfill multiple views in bulk

When having many configured views it is time consuming to perform backfill after a data outage. If a situation occur that require backfilling of data it is most likely that it will affect a mjority of the configured views that are set up. Today w...
Guest over 3 years ago in PI Integrators / AVEVA™ PI Integrator for Business Analytics 1 No status

Overwriting exports instead of appending them

Would like the ability to overwrite exports insteadof appending to them. Use Case: Have some jobs that should really just be overwriting (like if you want data to only exist for 7 days, doing T-7d to T) but also doing .csv exports. There current...
Guest over 3 years ago in PI Integrators / AVEVA™ PI Integrator for Business Analytics 1 No status

Configure PI Interface for Emerson-Ovation to read drop status points Ovation.

knowing in real-time if an ovation server is down and would help with maintaining the PI server.
Betty about 1 year ago in PI Interfaces / Other Interfaces 0 No status

Ability for PI Integrator to look into the future

It would be benefical if PI Integrator allowed data to be in the future. To be more proactive instead of reactive with metrics we would like to be able to push future looking data into PI. PI Vision and PI AF allow data for the future but PI Integ...
Nelson Worner over 2 years ago in PI Integrators / AVEVA™ PI Integrator for Business Analytics 1 No status

Retry connection logic for "Unhandled Exception" errors

If a publication fails due to "Unhandled Exception" errors, the Integrator will not attempt to reconnect until the the next publication is scheduled. This can cause a disruption in the target data while waiting for the data to come in. Adding a pa...
Housnat Aboubacar over 2 years ago in PI Integrators / AVEVA™ PI Integrator for Business Analytics 0 No status

PI Interface for Bacnet: Adding support of ObjectType=Timer

We would like to get a value of ObjectType=Timer object in PI BACNet interface but it is not supported. One of the Timer object contains important time setting and we need to check it every month. However currently we need to check the value from ...
Kenji Hashimoto over 1 year ago in PI Interfaces / Other Interfaces 1 Declined

Allow sending data to Apache Kafka target in XML Format using the PI Integrator for Business Analytics

It might be necessary to send data to Apache Kafka target in XML, because Consumers might need the data in XML format (altough it can be considered outdated). This would avoid the necessity to convert the data from JSON to XML as an additional ste...
Julian Baur over 3 years ago in PI Integrators / AVEVA™ PI Integrator for Business Analytics 0 No status

Create ArcGIS Feature Services and Layers with More Descriptive Names

Update the naming convention used to create ArcGIS feature services and layers to use names that more accurately reflect the services and layers stored on the Integrator side. Customer Issue: The current convention is to use numbers instead of the...
Guest over 3 years ago in PI Integrators / PI Integrator for Esri ArcGIS 0 Declined