Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

PI Adaptor for Perfmon

To move to next gen AVEVA tech, and perform a migration to Adaptors, critical monitoring with perfmon adaptor (Instead of Interface for PIPerfMon) would be ideal. Portability of using linux, docker etc. and having this data be available in AVEVA D...
Nick Ciampa 6 months ago in AVEVA™ Adapters / New Connectivity 1 No status

Enable AVEVA Adapter for OPC UA to detect unchanged source values beyond a configured interval and continue sending the last known value with refreshed timestamps until a new source event is received

This enhancement is required so the AVEVA Adapter for OPC UA can functionally match ABB 800xA / Vtrin RTDB historical behavior while preserving existing PI System and Asset Framework functionality. The customer would like this capability implement...
Claudia Sischin 5 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

OPC interface retries sending InstrumentTag/ItemID to OPC Server

The idea is to have PI Interface for OPC DA/HDA to be able to send again Instrument Tag/Item ID after a configurable time when OPC Server is not able to resolve it (AddItem failed). This would be a workaround for an OPC server issue and would help...
Guest about 4 years ago in PI Interfaces / PI Interface for OPC DA 3 No status

Add an option to disable endpoint validation between results of GetEndpoints and CreateSession

As discussed in OPC UA Adapter - Mismatch of Endpoints returned by GetEndpoints and CreateSession , in the OPC UA SDK 4.1.0+ endpoint validation was added to compare results returned in responses to GetEndpoints and CreateSession requests. The OPC...
Andrew Miu over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 2 Planned

Enable OmfEgress component to be configurable by instance (by component)

In our process we wish to send a different set of data to different PI environments. For instance we would like all data to egress to the PROD environment while only egress a subset of data to the DEV environment, in which we don't need all the da...
Guest about 4 years ago in AVEVA™ Adapters / General 7 Future consideration

Allow files to be processed similarly to, or better than, the PI Connector For UFL (in particular, allow data to be manipulated before using or archiving it)

The AVEVA Adapter For Structured Data Files is supposed to be the successor to the PI Connector For UFL, but they work differently enough that each can handle certain types of files better than the other. The AVEVA Adapter For Structured Data File...
Kenneth Barber about 2 months ago in AVEVA™ Adapters / AVEVA Adapter for Structured Data Files 1 No status

OSIsoft Python Library for data science

As a data scientist, I would like to be able to use a fully supported OSIsoft Python library without having to directly interface my Python script with a middleware. This OSIsoft Python library would be able to perform the same operations as PI Da...
Guest about 4 years ago in AVEVA™ PI System Access (PSA) / General 3 No status

Have the option to discover new data streams, auto-select them, and save data retrieved for them, all with a single query to the data source, similar to PI Connectors

Background + problem When PI Connector tries to save data for a tag that does not already exist (e.g. data for a new piece of equipment), it will create that tag automatically. This is very convenient, but it sometimes led to issues where data tha...
Kenneth Barber about 2 months ago in AVEVA™ Adapters / General 0 No status

Allow client-level failover on a per data source component level

Currently the client-level failover for Adapters occur on a per Adapter level. Which means that for instances where multiple data sources are configured, in some circumstances failover may result in an instance with a bad connection to a particula...
Miwa Teranishi over 1 year ago in AVEVA™ Adapters / General 1 No status

Before publishing documentation, please review it, from start to finish, to catch and fix most issues

Whether I was trying to learn about a product before using it or trying to configure a product, I ended up reading most of the documentation of several new or somewhat new AVEVA products, including: AVEVA Adapter For RDBMS AVEVA Adapter For St...
Kenneth Barber about 2 months ago in AVEVA™ Adapters / Help / Documentation / Videos 0 No status