Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Add functionality to the interface to adjust timestamps by a configurable amount

This enhancement would add the ability to adjust timestamps to the PI to PI Interface (Beyond the included options for clock drift and subseconds). Potentially, a setting could be supplied to change the timestamps on all data transferred by a spec...
Guest about 4 years ago in PI Interfaces / PI to PI Interface 1 No status

Allow OPC DA  Output Tags to capture OOO events

Currently there is no way to send corrected values to the OPC DA Server since they are triggered by snapshot. It would be useful if there was a way to alter the values that get sent in case there are substituted/replaced values.
Guest about 4 years ago in PI Interfaces / PI Interface for OPC DA 1 No status

Automatic restart of the OPC interface whenever OPC server is restarted

whenever the OPC server undergoes any restarts or configuration changes, the OPC interface will delete all old connections, groups, etc. and it will establish a new connection to the OPC server, loading all ItemID's etc (as if it is an automatic r...
Guest about 4 years ago in PI Interfaces / PI Interface for OPC DA 2 No status

Include Windows Counters/OMF Health for Message Log Event Rate

Having metrics that count the number of messages being written to the message log, and categorized by severity, gives a great dashboard overview of the status of PI data archive. For example, having a events/min count of error messages historized ...
Mike Horrocks about 2 years ago in AVEVA™ PI Server / Data Archive 0 No status

Allow PI AF Analyses to reference PI Vision dashboard start time

PI AF attributes can summarize other PI Point attributes across a time range using value retrieval methods and setting the "TimeMethod" parameter to "TimeRange". When a PI Vision dashboard references these summary attributes, it overrides the time...
Greg Malek 9 months ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

PI Notifications automated emails need to display all receivers of the automated emails from the PI Notifications application, not just the singular user (me in this case).

PI Notifications automated emails need to display all receivers of the automated emails in the list of emails that the automated email was sent to. It is very important for the user (or receiver of the automated PI Notification email) to understan...
Phil Jones almost 3 years ago in AVEVA™ PI Server / Notifications 1 No status

Segment PI Tag Delete Permissions

Want to be able to allow some users the ability to create and modify tags, but to avoid the issues with deleted tags being hard to recover or accidents, remove their ability to delete tags. Currently, PI Tag Security has only two options: Read/Wri...
PriceN over 1 year ago in AVEVA™ PI Server / Data Archive 0 No status

"Connect As" to the Analysis Service From PI System Explorer

The "Connect As" feature only changes the Asset Framework Connection and still uses the user who runs the application to connect to the Analysis service. This causes a confusion for end users as they cannot perform their analyses operations (e.g. ...
Mohammed Qasim Asghar 9 months ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

Dynamic EF root cause duration

To avoid creating several templates, suggested adding the possibility to choose the duration In the Event Frame-->Advanced Event Frame Settings-->Generate child root cause event frame before parent event frame starts, to be different for eac...
Gilbert Nassif almost 4 years ago in AVEVA™ PI Server / Event Frames (EF) 0 No status

Analysis service installer

When upgrading the PI analysis/notification service in a clustered environment, it prompts you to change the configured analysis/notification service. In a clustered environment, this breaks the configuration and requires an PI admin to go back an...
GaryYegiazaryan 10 months ago in AVEVA™ PI Server / Installation 0 No status