To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 376 of 5219

AutoPointSync for OPC DA should work on 64bit servers.

AutoPointSync for OPC DA does not install or run correctly on 64bit servers. As most new servers are 64bit this would seem to be an essential capability.
zubzub over 3 years ago in PI Interfaces / PI Interface for OPC DA 1 No status

change the default behavior of the OPC DA interface to use /DC

per the OPC DA 2.x spec, the OPC server will call us back for all points that have a changes; even those points where we are polling. We have a switch to disable the callbacks for points that are not set to advise: /DC Can we make that the defau...
Clint Ramsey over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

PI OPCtoCSV Tool: Subbranch filter depth

The PI Interface for OPC DA is packaged with the PI OPCtoCSV tool which extracts all OPC Items. It is possible to filter the items by subbranch however it recurses all sub-subbranches. We have an OPC server with around 20k items that we read into ...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

PI interface for OPC .. UA

it would be useful to have an interface that can connect and retrieve data from OPC UA server. it will help to avoid using any additional software for "downgrading" the protocol to OPC at client side.
ValterFostini over 3 years ago in PI Interfaces / PI Interface for OPC DA 2 No status

Create a TriggeredOn() function for PI Analysis

The TriggeredOn() function would return true if the inserted attribute was the reason for the expression analysis to trigger/evaluate. I have multiple attributes in the same analysis but only want each line to have an output when its corresponding...
Ian Morgenstern 12 months ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Analysis Preview Results - Remove Table and Graph

When using the preview analysis function an an analysis with many variables the preview graph and table struggles to keep up, and uses a long time to update. When there are many variables, these are also quite useless. It would therefore be an i...
Haavard over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 2 Declined

Logic for SQC calculations

I would like the ability to flag an SQC event only if I am in a batch, on a grade run, or in some other process condition. Right now, I am getting an SQC outside control limit when my phase is "inactive." Let there be more configuration of this in...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Analysis service should not close opened EF when last evaluation time is exceeds MaximumAllowedAutoBackfillingSpanInHours

As PI server administrator I would like that when the Analysis service is restarted with autobackfilling enabled, if there are any EF analysis where last evaluation time is older than *-MaximumAllowedAutoBackfillingSpanInHours, EFs that are opened...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Filter/Flag PI System Generated Error Message as Analysis Inputs to prevent False Positive Evaluations

The PI data archive (and potentially other systems) can generate many automated error messages to assist with troubleshooting. One such key example is "[-10767] Client exceeded maximum concurrent queries in RPC thread pool", which occurs when a se...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Abililty to minimise Preview result window

When you develop an expression it is very useful to use the preview function. Quite often you can discover and debug directly from this, but you are not abel to close down the window and check the code! So either you memorise or you export the cs...