To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 129 of 5193

If data contains asset information, this data shall be written to asset related streams

Challenge: We have (CSV) data files which come from Laboratory or other measuring equipment where the data lines contain information on which asset the measurement was taken from. In our particular use case, we read sample data from lab analyzer w...
Hans-Otto Weinhold about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Structured Data Files 0 No status

PI Adapter for Structured Files - User friendly interface

Make the configuration experience more user friendly. Add a user interface for adapter configuration and management.Today, this adapter is too configuration intensive
Guest over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Structured Data Files 0 No status

PI Adapters should not overwrite parameters configured in the stream in ADH

When we change any override parameters for a stream in ADH an adapter restart will overwrite what we configure in the stream. One example is changing the interpolation method for a stream in ADH because we want to see the trend as step. Every time...
Fabio Dani over 2 years ago in AVEVA™ Adapters / General 0 No status

Accept HEX numbers for Register offsets in data selection

Most modbus equipment providers provide information using registers in Hex format i.e. 0x0000 ~ 0xFFFF. It would be nice if the offset could accept this to avoid error in conversions HEX to DEC. Would make things alot more seamless/easier.
Matthew Kishe almost 3 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 Future consideration

ORC, parquet and avro file format support

Customer files from on-premises systems are delivered to the cloud in ORC format for ingestion into Data Hub
Guest about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for Structured Data Files 0 No status

New start-up parameter /SYNC_TIME defining a floating-window during which the interface will keep a RDB table in sync with PI data archive

The new RDBMSPI param:  /SYNC_TIME=rel_start_time,rel_end_time   for instance /SYNC_TIME=*-6h,*+1h When set, the interface: - after each execution of a query, which shall have the same "floating" window in its WHERE clause; for insta...
Guest over 3 years ago in PI Interfaces / PI Interface for RDBMS 1 No status

Accept the dd-mmm-yyyy format in the absolute time syntax for history recovery start and end times

The PI Interface for RDBMS currently accepts the format dd-mmm-yy but not the format dd-mmm-yyyy for history recovery start and end times. The former format lacks the century, so the year is ambiguous. The latter format solves this problem and so...
Kenneth Barber over 3 years ago in PI Interfaces / PI Interface for RDBMS 0 No status

History recovery from multiple tags with one output tag

I have a scan-based output point writing multiple PI values to the relational database as described here: https://livelibrary.osisoft.com/LiveLibrary/content/en/int-rdbms-v4/GUID-1A194D2B-388B-4FD7-8B82-D85EDDBBC572 I would like to perform histo...
Guest over 3 years ago in PI Interfaces / PI Interface for RDBMS 0 No status

Improved handling of PIBUFSS initialization

We have encountered a situation where we were unable to write out-of-order data to PI through the buffer subsystem from an interface, apparently because the buffer subsystem was not yet fully initialized when the interface connected to it. Please ...
Guest over 3 years ago in PI Interfaces / PI Interface for RDBMS 0 No status