To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 139 of 5259

Provide additional time formatting options for RDBMS Queries

Background: Today we are collecting data from our AspenTech IP21 Server thorugh the PI Adapter for OPC UA and the related AspenTech OPC UA Server. This works perfectly fine for analogue data but not for data which is providing us equipment status ...
Hans-Otto Weinhold over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for RDBMS 1 Tell us more

Enable the ability to use the UserInt1 to propagate PI to PI APS source tag name changes to the target if source collective Data Archive-level failover is configured

UserInt1 attribute contains source point ID. (Illegal configuration if source Data Archive-level failover is configured.) Source tag mapping by point ID is not compatible with Data Archive-level failover.
Guest over 2 years ago in PI Interfaces / PI to PI Interface 0 No status

Better support of IP21 OPC UA Server with PI Adapter for OPC UA

We have been using the PI Adapter for OPC UA in its current version to collect data from IP21 OPC UA Server during a lighthouse project. However, the configuration was a bit cumbersome since the OPC UA Server of AspenTech uses an opaque mechanism ...
Hans-Otto Weinhold over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Supress PI-APS messages for Error -2147220428: Failed to create point on server. [-10550] Tag Already Exists in Table

Seeing "information" messages in PI-SDK related to "Error -2147220428: Failed to create point on server. [-10550] Tag Already Exists in Table" which is irrelevant to see in the logs. If one source instance sending to multiple destination instances...
AshwinC over 2 years ago in PI Interfaces / PI to PI Interface 1 Future consideration

Make a BACnet/SC adapter

BACnet/SC is essentially the same as BACnet/IP... but secures the communication
Nate Anderson almost 3 years ago in AVEVA™ Adapters / AVEVA Adapter for BACnet 1 No status

Allow multiple references to holding register for bit extraction

Given a 16bit integer holding register, in certain instances we only care for specific bits rather the integer value. Using the bitmap allows the selection of those specific bits but you can only reference the register once. i.e. In data selection...
Matthew Kishe about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 8 Future consideration

AVEVA Adapter for WITSML

We need an Adapter for WITSML to get data from drilling, completions, and interventions of oil wells to CONNECT data services, so the data can be shared between multiple stakeholders.
Guest over 1 year ago in AVEVA™ Adapters / New Connectivity 0 No status

PItoPI: Disabling Time adjustment

the ability to disable the timezone adjustment. currently we are calculating daily kpis on our global pi server. with PItoPI we are sharing it to the site pi-servers. so the daily kpi for e.g. 1st januar 2019 00:00AM sould alwas have that timesta...
MichaelHuber over 3 years ago in PI Interfaces / PI to PI Interface 1 No status

CONNECT Agent for AVEVA Plant SCADA (Citect)

AVEVA Plant SCADA 2020r2 and newer, has an OPC UA Server, so the AVEVA Adaptor for OPC UA can be used to send data to CONNECT data services (AVEVA Data Hub). However native connectivity like the PI-to-CONNECT Agent or the System Platform Connector...
Guest almost 2 years ago in AVEVA™ Adapters / New Connectivity 0 No status

Allow the BACnet Adapter to handle responses with an LVT that does not match the request

Currently the BACnet Adapter expects devices to respond with the same "Length Value, and Type" (LVT) value as the request. When this occurs the BACnet Adapter cannot parse the data in the response. For example: Request from Adapter, LVT=1 Response...
Nico Cha almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for BACnet 0 No status