Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 40 of 5192

Source and destination tag mapping list

Customer would like the ability to have PItoPI create a list of tags that includes the FULL name of the source tags, as well as the destination tags they are mapped to.  This will greatly assist in managing tags that are being sent to a remot...
Guest over 3 years ago in PI Interfaces / PI to PI Interface 0 No status

Enable the ability to use the UserInt1 to propagate PI to PI APS source tag name changes to the target if source collective Data Archive-level failover is configured

UserInt1 attribute contains source point ID. (Illegal configuration if source Data Archive-level failover is configured.) Source tag mapping by point ID is not compatible with Data Archive-level failover.
Guest over 2 years ago in PI Interfaces / PI to PI Interface 0 No status

Supress PI-APS messages for Error -2147220428: Failed to create point on server. [-10550] Tag Already Exists in Table

Seeing "information" messages in PI-SDK related to "Error -2147220428: Failed to create point on server. [-10550] Tag Already Exists in Table" which is irrelevant to see in the logs. If one source instance sending to multiple destination instances...
AshwinC over 2 years ago in PI Interfaces / PI to PI Interface 1 Future consideration

Do not bundle PI Adapters with EDS

Reduce the footprint of EDS by not bundling adapters with EDS but instead have them be a separate installation so only the desired adapters end up being installed on the device. It will also allow easier for a clearer process when an adapter needs...
Gabriel Verreault over 3 years ago in Edge Data Store / Installation 1 Future consideration

PItoPI: Disabling Time adjustment

the ability to disable the timezone adjustment. currently we are calculating daily kpis on our global pi server. with PItoPI we are sharing it to the site pi-servers. so the daily kpi for e.g. 1st januar 2019 00:00AM sould alwas have that timesta...
MichaelHuber over 3 years ago in PI Interfaces / PI to PI Interface 1 No status

Don't change product version information response structure

The design of the /productinformation response has changed between EDS 2020 and EDS 2023 Patch 1. Our application missed the new position of the version string so I had to change code to catch it. I know the product has shipped so there is nothing...
Guest over 2 years ago in Edge Data Store / General 1 Declined

Swagger.json v0.3.1.0 CTP 2 shows errors in Swagger Editor

Swagger.json in EDS Version 0.3.1.0 CTP 2 produces semantic errors when trying to generate a client using Swagger editor
Guest over 3 years ago in Edge Data Store / General 0 Declined

Retrieve EDS Data Egress Status through REST API call

It would be great to have a REST API call available in EDS to get the current data egress state rather looking it up through the logfiles. The idea is to get information about when data was (successfully) egressed to OCS, AVEVA Data Hub or the PI ...
Guest over 3 years ago in Edge Data Store / Egress 1 Tell us more

PI to PI interface should perform first scan so that future data can recovered

/fd parameter is only used while performing real-time scan. If scan rate is set to a higher value such as a day, the user would need to wait for the first scan (after a day) to get future data. This should be done at interface startup. For use cas...
Guest over 3 years ago in PI Interfaces / PI to PI Interface 0 Declined

Provide data validation tools to verify moving history from one PI Server to another using PI to PI Interface

There is no easy way to verify that historical data moved from one PI Server to another using the PI to PI Interface isn't missing data on the target PI Server.
Guest over 3 years ago in PI Interfaces / PI to PI Interface 0 No status