To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Allow attribute annotations to be published with the Integrator

I want to publish the attribute annotation for a time series event using the Integrator. For example, if a user enters data in PI Manual Logger, they enter comments as annotations to the tag event. I would like to publish those annotations along w...
Guest almost 4 years ago in PI Integrators / AVEVA™ PI Integrator for Business Analytics 3 No status

Add failover / high availability for the PI to AVEVA Data Hub Transfer Agent

Right now, the Transfer Agent is a single point of failure. We need to be able to install at least one additional Transfer Agent, on a separate host, so that we can guarantee that our PI System data will arrive in AVEVA Data Hub. This will also al...
Daniel Lopez almost 3 years ago in PI to CONNECT / General 0 No status

Transformation and Scaling for OPC UA Adapter

Implement transformation and scaling for OPC UA adaptor the way it exists for PI OPC DA interface tags. The user can modify egressed tags and the data will be transformed / scaled when egressed.
Guest almost 4 years ago in AVEVA™ Adapters 4 Future consideration

PI Adapter for AspenTech IP21

We have customers who are using AspenTech IP 21 and would like to have data replicated in both PI DataArchive and OCS in the future. Since the PI Interface is a bit outdated, a new PI Adapter would make perfect sense (since there is already a PI C...
Guest almost 4 years ago in AVEVA™ Adapters / New Connectivity 4 Tell us more

Add ability to uncheck or remove attributes from existing transfer

Transfers are initially added by searching and then selecting elements then attributes to add. When we want to edit the transfer, we are only able to remove entire elements, not by attributes. This became an issue when we later found that we had a...
Guest over 1 year ago in PI to CONNECT / General 0 No status

Please add a feature for the OPC UA adapter to enable the adapter to only store values with a good status or rather filtering out bad values

When receiving bad values from the OPC UA Server to the adapter there is no option to filter out bad values. So these values get stored in the Data Archive and are causing problems with analyses (e.g. expression or Event Frame generation). At the ...
Timur Eroglu over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Allow PI Integrator to create a new file per publication in Amazon S3

As a PI Integrator user, I'd like PI Integrator to create a new file per publication in Amazon S3. Currently there is a workaround with Maximum Rows/Objects option in target configuration, but it is not straightforward and cumbersome.
Guest almost 4 years ago in PI Integrators / AVEVA™ PI Integrator for Business Analytics 2 No status

Modifying an integrator view should lead to its target conserving already existing historical data

Currently, if an integrator view is already created on a target (for example SQL) and then a user needs to modify the view to add one or more columns to the target table - A fresh table will be created for the modified view containing the newly ad...
Guest 6 months ago in PI Integrators / AVEVA™ PI Integrator for Business Analytics 0 No status

Allow AVEVA Adapter for Modbus TCP to collect data on INT64 and UINT64 registers

Certain equipment is providing energy data under INT64 or UNIT64 register types. However, the Adapter currently only supports FLOAT64, which is not compatible. We want to be able to configure the Adapter for Modbus TCP to collect data on INT64 and...
Alexa Derago 11 months ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 Future consideration

Adapter to failover when there is egress issue

When connection to the datasource are all good for all the adapter failover members, but the primary adapter having issue connecting to the PI web API (egress) for example, adapter does not failover. Unlike PI Interface UNIINT failover, when there...
Ee Sheing Lee almost 3 years ago in AVEVA™ Adapters / General 2 No status