To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Provide more detailed error logging

Error message logs sometimes are not detailed enough to properly troubleshoot. The customer would like to increase logging available in order to get more insight as to what is going on. One example - the PI Integrator for BA does not publish any...
Guest over 3 years ago in PI Integrators / AVEVA™ PI Integrator for Business Analytics 3 No status

Send a notification if a view fails to publish successfully

As a user, I would like a notification or email when a view did not succeed so that I can take action to backfill or triage the situation.  Currently I can only use the Last Run Time and it takes a long time to verify when each view's expecte...
Guest over 3 years ago in PI Integrators / AVEVA™ PI Integrator for Business Analytics 0 No status

Allow configurable column size (nvarchar) when publishing to a relational table

The current default column size is 4000 characters. It would be nice to allow the user to have control over this parameter.
Roger Ward over 3 years ago in PI Integrators / AVEVA™ PI Integrator for Business Analytics 0 Declined

Support latest Oracle database and ODAC version

As a user who publishes to Oracle, I would like the PI Integrator to support the latest Oracle database and ODAC versions so that I can take advantage of Oracle bug fixes. For example, the PI Integrator 2020 version supports only ODAC 12.1.0.2.4 ...
Guest over 3 years ago in PI Integrators / AVEVA™ PI Integrator for Business Analytics 1 No status

PI System Connector should disable/enable existing connections to PI Connector Relay

Operating in a validated pharmaceutical industry, when making use of a comprehensive data/asset centralizing approach, we require the PI System Connector (PSC) to disable existing connections to PI Connector Relay when routing it to a new PI Conne...
Christian Leroux over 3 years ago in PI Connectors / PI System Connector 0 No status

Custom Time Range for OPC UA History Read (Recovery)

It would be very useful for to be able to specify a custom time range to do a history read for on the PI Connector for OPC UA . The connector automatically does this recovery for time intervals that it internally identifies as gaps. However, many ...
Drew Hoffman about 3 years ago in PI Connectors / New PI Connector Request 0 No status

PI OPC UA Connector to write Bad Input/Configure

PI OPC UA Connector to write Bad Input/Configure when the respective NodeId is no longer available in OPC UA Server.
Fnu Safdar 5 months ago in PI Connectors / PI Connector for OPC UA 0 No status

trend log objects (BACnet object type 20) available from the connector

BACnet trendlog object present the opportunity to buffer at the edge where the data is collected and to gracefully recover from comms outages if data collection has been impacted. I would suspect the trendlog object could be handled similarly to ...
Guest over 3 years ago in PI Connectors / PI Connector for BACnet 0 No status

Wonderware Historian Connector should store some metadata in PI tag attributes

The Description, Maximum EU, Minimum EU, Engineering Units, etc. that are stored in the Wonderware historian should be stored in the PI tags' attributes as well as the Wonderware AF structure.
Guest over 3 years ago in PI Connectors / PI Connector for Wonderware Historian 1 No status

Add instrumentation to the PI System Connector

Need to add instrumentation to PI System Connector wheras exposing perfmon counters (so PI perfmon can store accordingly in PI tags) on AVG data flow in events/sec for a 120 seconds time period, status of the connector, etc
Guest over 3 years ago in PI Connectors / PI System Connector 1 Declined