To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 331 of 5258

Custom HTTP header

add functionality so will bepossible to configure the PI Adapter for OPC UA to include a custom HTTP header when authenticating requests to the PI Web API endpoint The request for this feature recently came up in a support case for PPC (Dev CR: CR...
Dimitrios Pilos 9 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 Future consideration

Please have PI Integrator for Business Analytics supports high availability (HA)

As a user of PI Integrator for Business Analytics, I'd like to have it support high availability (HA).
Guest over 3 years ago in PI Integrators / AVEVA™ PI Integrator for Business Analytics 8 No status

PI Adapter for OPC UA Array Support

As a PI System Administrator, I would like for the PI Adapter for OPC UA to support array data types from the OPC UA Server. A large amount of our data may be contained within arrays on our OPC UA Server, so we would not currently be able to colle...
Guest over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 12 No status

Bitmask Functionality in AVEVA PI OPC UA Adapter

During the migration from the PI OPC DA Interface to the AVEVA PI OPC UA Adapter, we noticed that the ability to apply bitmasks to incoming values is no longer supported. This functionality is critical in many existing implementations, especially ...
Dennis Fendel 8 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 Future consideration

Include buffering metrics in adapter health

In the OmfEgress component in adapter health the metrics are limited to DeviceStatus, and IO rate. Another key metric for this component is the buffering state. To keep it simple it would be useful to have the number of events in the buffer. This ...
Mike Horrocks 12 months ago in AVEVA™ Adapters / General 0 No status

Automatically remove data from continuous views

As an engineer using PI View or SQL writers for a report, I would like option to remove data older than a certain cutoff. For example, a continuous view is used to generate data for a report on the last 8 hours. Data older than that are no longer ...
Guest over 3 years ago in PI Integrators / AVEVA™ PI Integrator for Business Analytics 8 No status

Provide Bulk Column Configuration

The current method for adding columns and changing their Data Content type (value, average, min, max, etc) is clunky and time consuming.  You can only change (or add) one column at a time, and you have to wait for the data view to refresh aft...
Guest over 3 years ago in PI Integrators / AVEVA™ PI Integrator for Business Analytics 7 No status

Allow remote configuration

Adapters are currently only listening on localhost (127.0.0.1) causing them to be only accessible locally. For docker containers, they can only be accessed from within the container or directly on the host (with the --network host switch which res...
Gabriel Verreault over 3 years ago in AVEVA™ Adapters / General 3 Future consideration

Error handling for OPC UA Server nodes with "Null" data type

Using a combination of Honeywell Experion OPC UA and the Aveva OPC UA Adapter, we have observed that when an instrument physically fails in the field or goes offline / stops sending communication to the Experion server, it may appear in the Honeyw...
ChrisMcKee about 2 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Pi adapter OPCua able to rename pi-tags

As per title
Rob Chew 3 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 3 Tell us more