Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Stream-level debugging

As a PI System Administrator, I'd like to be able to trace values being received, and subsequently being sent by the Adapter, similar to PI Interfaces. Having the ability to trace/log timestamps and values for specific streams would greatly help ...
Guest over 4 years ago in AVEVA™ Adapters / General 0 Future consideration

Expand Healthpoint (Device Status) Information of the PI Adapter for Modbus TCP from Component to "Device" Level

When configuring PI Modbus TCP adapter you first define a component level and under this type you define your different devices/machines/sensors. In case of a broken connection to one of the devices the healthpoints currently only deliver the stat...
Mario Amrhein almost 3 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Adapters using Text parser be able to dynamically generate the stream name or ID based on fields of the text parsed

This could be a good feature for any adapters that uses the text parser. MQTT, SDF, Azure Event Hubs. When using JsonPath or Xpath to parse a file or payload the stream name and stream id have to be hardcoded their value cannot be based on a the v...
Randy Giguere almost 3 years ago in AVEVA™ Adapters / General 0 No status

Improve the message for performing on demand History Recovery on datacollectionmode: "CurrentWithBackfill" and "CurrentOnly"

Running edgecmd to perform HR on demand on the datasource: datacollectionmode of Non HistoryOnly. will return the following error: Operation Failed: NotFound (404)Unexpected error: Unexpected character encountered while parsing value: 0. path '", ...
Ee Sheing Lee over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Configurable Hostname/IP Identifier for OMF Health Egress

The health tags and AF structure is created with the following naming pattern by default: <machine hostname>.<adapter type> To support modern containerized deployment models, please consider adding a configurable field that allows cust...
Bharat Rawat 9 months ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

Enable Adapter for OPC UA to use the Pub/Sub method

Pub/Sub is proposed to be a more efficient and scalable method of transferring data using OPC UA. Allowing the adapter to access data in this way would increase the options for data collection, and allow the OPC UA adapter to be used in many more ...
Mike Horrocks over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Permit non-protected references

The secrets references is a very useful addition but they are only permitted for "protected" parameters. It would be useful to also create references for non-protected parameters. Using references for non-protected parameters would help with creat...
Mike Horrocks over 3 years ago in AVEVA™ Adapters / General 1 No status

Allow PI Adapter for MQTT to log the raw json payload received from the broker

For troubleshooting, it can be very helpful to see the raw json payload that the adapter has received from the broker, rather than just the error response from the attempted parsing. It can be difficult to know why a parsing attempt has failed wit...
Guest over 4 years ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 2 Future consideration

More control on MQTT parameters on the AVEVA Adapter for MQTT

It would be nice to have more control on additional MQTT parameters for the AVEVA Adapter for MQTT. We are especially interested in having control on the QoS of the subscription. Setting this would give us more control in buffering, especially whe...
Tombayu Hidayat almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 1 No status

Support for the Galileosky Protocol

Need an option for direct integration of Galileosky GPS tracking devices with the AVEVA PI System without third-party middleware. The devices primarily use the proprietary Galileosky binary protocol (TCP-based, port 20332 by default) for real-time...
Mohammed Qasim Asghar 12 months ago in AVEVA™ Adapters / New Connectivity 0 No status