To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 126

Enable PI Web API to utilize failover with a partner

In using a PI-MQTT Adapter, they can be joined in failover. And then adding to the data stream PI Web API, it does not support failover currently. Which leads to one node in the stream that does not have a failover partner.
Matt Steben 4 months ago in AVEVA™ PI System Access (PSA) / PI Web API 0 No status

PI WEB API - Swagger page

It would be great if as an addition to conventional documentation there was a SWAGGER page with short explanation of methods and parameters (including return types, etc.)
Guest over 3 years ago in AVEVA™ PI System Access (PSA) / PI Web API 2 No status

Pi adapter OPCua able to rename pi-tags

As per title
Rob Chew 3 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 3 Tell us more

Update PI Web API with AF SDK supporting .NET 10

With the announcement of a new .NET 8 AF SDK at AVEVA World 2023 coming sometime in 2024, we would like to see a new version of the PI Web API that adopts this new version.
Alec Lord about 2 years ago in AVEVA™ PI System Access (PSA) / PI Web API 4 Planned

Error handling for OPC UA Server nodes with "Null" data type

Using a combination of Honeywell Experion OPC UA and the Aveva OPC UA Adapter, we have observed that when an instrument physically fails in the field or goes offline / stops sending communication to the Experion server, it may appear in the Honeyw...
ChrisMcKee 3 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

OPC UA Adapter Create Tag on Discovery

For the OPC UA Adapter, we are noticing that a tag won't be created until a data point comes in after the tag is added to the data filter. That causes issues for slow updating tags. For instance an open/shut valve that is rarely operated. We have ...
Damon Vinciguerra 8 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Future consideration

Add an option to disable endpoint validation between results of GetEndpoints and CreateSession

As discussed in OPC UA Adapter - Mismatch of Endpoints returned by GetEndpoints and CreateSession , in the OPC UA SDK 4.1.0+ endpoint validation was added to compare results returned in responses to GetEndpoints and CreateSession requests. The OPC...
Andrew Miu 9 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Planned

Implement a checkpoint system for index crawls

When the crawler fails on an incremental crawl, the index search must perform a complete rebuild of the index. It would be beneficial for there to be a way to revert to a previous built index just prior to the failed incremental crawl so that the ...
Guest over 3 years ago in AVEVA™ PI System Access (PSA) / PI Web API 2 Declined

Sampling/Publishing Interval parameters to be part of Data Selection description

When configuring the AVEVA Adapters in general, we would find more convenient to be able to define the ‘Sampling Interval’ and 'Publishing Interval' parameters inside the ‘Data Selection’ configuration per each data stream. For instance, when desc...
Christian Leroux almost 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Please add a feature for the OPC UA adapter to enable the adapter to only store values with a good status or rather filtering out bad values

When receiving bad values from the OPC UA Server to the adapter there is no option to filter out bad values. So these values get stored in the Data Archive and are causing problems with analyses (e.g. expression or Event Frame generation). At the ...
Timur Eroglu about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status