To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 172 of 5257

option to not collect quality

Quality is not supported by the OPC UA Server/always zero.
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Tell us more

Support OPC UA ReverseConnect

Support ReverseConnect, allowing for the connection to be establish from the more secure area where the OPC Server reside to the least secure area where the OPC Client / Adapter resides. This is implemented in many other client tools and SDK such...
Gabriel Verreault over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

PI adapter for PI-to-PI

We need a new robust product to support data transfer between PI servers in separate domains (operational network --> business network). This product would need to support the following: Highly available remote management/deployment multiple in...
GaryYegiazaryan over 2 years ago in AVEVA™ Adapters / New Connectivity 3 No status

PI Adapter High Availability Resilience

Problem Summary: The client failover service for PI adapter is not highly available. If the client failover service node is unavailable, then the PI adapter instances that it manages will lose failover functionality. This is further exacerbated if...
GaryYegiazaryan over 2 years ago in AVEVA™ Adapters / General 1 No status

Adapter for OPC UA to support Global Discovery Server

Currently, to manage the OPC UA Server/Adapter certificate, we have to manually move the certificate or get the certificate trusted beforehand. This is expected for self signed Application certificate for both the Server and the Client (Adapter). ...
Ee Sheing Lee 8 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 2 Tell us more

Support of complex streams with PI Adapter for RDBMS with free attribute selection

Background: Today we are collecting data from our AspenTech IP21 Server thorugh the PI Adapter for OPC UA and the related AspenTech OPC UA Server. This works perfectly fine for analogue data but not for data which is providing us equipment status ...
Hans-Otto Weinhold over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for RDBMS 2 Planned

Programmatic Access to Datalink Settings

Create a way to programmatically set the Datalink Settings so that they can automate excel reporting more effectively
Guest over 3 years ago in AVEVA™ PI DataLink™ / Programming 1 Declined

can we ad normal files as hyperlinks to buttons from a local networkdisk

( example --> S:\pictures\tankfarm.jpeg ) with pi processbook it was possible , with pi-vision i didn't find yet !
Guest almost 2 years ago in AVEVA™ PI DataLink™ / Functions 1 No status

PI DataLink on MS 365

It will be great to have PI DataLink Add-on works on Microsoft 365 or allowing PI DataLink reports to be hosted in PI Vision.
Husain Al-Shaikh over 1 year ago in AVEVA™ PI DataLink™ / Programming 0 No status

Add calculation options to Calculated Data to match PSE

As an end user, I would like to choose calculation options other than time-weighted and event-weighted so that I can override the default processing of continuous or discrete. This functionality is currently available in PI System Explorer | Time ...
Jeremy Roberts over 3 years ago in AVEVA™ PI DataLink™ / Functions 1 Declined